CENTENNIAL, CO —
OSHA Inspection: TOY CAR CARE, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of TOY CAR CARE, INC. in 6844 S POTOMAC ST, CENTENNIAL, CO 80112 (NAICS 811111). OSHA activity number 340488014.
Where did this inspection happen?
- Establishment
- TOY CAR CARE, INC.
- Site address
- 6844 S POTOMAC ST
- City
- CENTENNIAL
- State
- CO
- ZIP
- 80112
- Mailing
- 6844 S POTOMAC ST, CENTENNIAL, CO 80112
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811111
- Employees
- 12
- Ownership type
- A
Citations
6 citations on file for this inspection.
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1000.00 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to crushing and struck-by hazards while using an automotive lift: (a) On or about March 19, 2015, and at times prior the employer did not ensure that employees were safe from crushing and struck-by hazards in that the following lifts were noted with deficiencies: (1) Rotary lift, model SPOA9-200, serial #SPA000D0812, was not lowered to rest on the locking mechanism while the lift was raised and in use. (2) Rotary lift, model SPOA9-200 Serial #SPA00B3080, was not lowered to rest on to the locking mechanism while the lift was raised and in use. (3) The employer did not document that all lift users were trained to use the lifts in that rotary lifts were not lowered to rest on the locking mechanisms while in use. (b) Auto lifts were not periodically inspected by a qualified inspectors at least annually to ensure that they were properly maintained and functioning. Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1910.215 A04
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $800.00 Reduced
General-duty citation text
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch: (a) On or about March 19, 2015, the employer exposed employees to stuck-by hazards due to the bench grinder work rest, located in the automotive bay area, not being adjusted to one eighth inch. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $800
- — Z (S) $1600
1910.215 B09
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: (a) On March 19, 2015, the employer exposed employees in the automotive bay area to struck-by hazards due to bench grinder tongue guards exceeding one fourth inch. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.106 E09 III
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.106(e)(9)(iii): Combustible waste material and residues in a building or unit operating area were not kept to a minimum, stored in covered metal receptacles and disposed of daily: (a) On or about March 19, 2015, the employer exposed employees to fire hazards in that the covered metal receptacles containing combustible oily rags, were not disposed of on a daily basis. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.303 G01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: (a) On or about March 19, 2015, the employer did not maintain a clear distance of 3 feet in front of the circuit breaker panels and transformers in order to provide access for emergency maintenance. Abatement Note: Abatement certification is not required for this item.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 H03 IV
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(h)(3)(iv): The details of the hazard communication program developed by the employer, did not include an explanation of the labels received on shipped containers and the workplace labeling system used by their employer; the safety data sheet, including the order of information and how employee could obtain and use the appropriate hazard information: (a) On or about March 19, 2015, and at times prior, the employer did not train employees on the new label elements, signal words and safety data sheets format that was required to be completed by December 1, 2013. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 811111)
LONGVIEW, WA—2026-07-09
WA317992006 - LONGVIEW AUTO REPAIR LLC
HOUGHTON LAKE, MI—2026-07-08
WILSON'S AUTOMOTIVE
KELSO, WA—2026-07-08
WA317991989 - THOMAS TRANSMISSIONS LLC
BURTON, MI—2026-07-07
AMERICA'S MOST WANTED 4X4
FISHERS, IN—2026-07-07
PEP BOYS AUTO SERVICE & TIRES
More inspections in CO
CASTLE ROCK, CO—2026-07-10
MASTER MAGNETICS, INC.
STRASBURG, CO—2026-07-08
JUNIOR ROOFING LLC
FORT COLLINS, CO—2026-07-08
EDWARDS SEMICONDUCTOR SOLUTIONS LLC
CENTENNIAL, CO—2026-07-08
JORDY CONSTRUCTION
HIGHLANDS RANCH, CO—2026-07-08
HOWELL CONSTRUCTION
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340488014.