Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: JOSE E. LUCIO-GARCIA

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JOSE E. LUCIO-GARCIA in 1 HOLLOW WAY, NEWNAN, GA 30265 (NAICS 238130). OSHA activity number 340489186.

Watch Jose E. Lucio-Garcia — free Get an email when a new federal OSHA severe-injury report for Jose E. Lucio-Garcia is published. One employer, no account, unsubscribe in one click.
Site address
1 HOLLOW WAY
City
NEWNAN
State
GA
ZIP
30265
Mailing
5872 NEWNAN COURT, AUSTELL, GA 30106
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
5
Ownership type
A

5 citations on file for this inspection.

1926.300 B02

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $2000.00 · Current $1200.00 Reduced
29 CFR 1926.300(b)(2): Moving part(s) of equipment exposed to contact by employees or which otherwise created a hazard, were not guarded:    (a) Street in front of Lot #14, new residential construction located at 1 Hollow Way, Newnan, GA 30265: Employee was exposed to amputation hazards while operating a Jenny Air Compressor (Model KU) without a belt guard and a guard over the starter recoil on the Honda engine powering the compressor.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1926.304 D

Serious Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $2800.00 · Current $1680.00 Reduced
29 CFR 1926.304(d): Portable, power-driven circular saw(s) were not equipped with a guard above and below the base plate or shoe:    (a) Front side, new residential construction located at 1 Hollow Way, Newnan, GA 30265: Employee was exposed to amputation hazards while cutting 1/2-inch OSB plywood sheathing with a Makita (Model 5007F) 7-1/4-inch Circular Saw with the lower guard propped open with a wood shim.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

1926.501 B13

Serious Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $2800.00 · Current $1680.00 Reduced
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m)  or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501 (b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502:     (a) Second floor top plate, new residential construction located at 1 Hollow Way, Newnan, GA 30265: Employee working from the top plate at heights of approximately 19-feet, 5-inches engaged in framing activities was not protected from falls.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

1926.1053 B01

Serious Gravity 5 1 instance 3 exposed
Issued
Penalty
Initial $2000.00 · Current $1200.00 Reduced
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access:    (a) First floor stairwell, new residential construction located at 1 Hollow Way, Newnan, GA 30265: Employees were exposed to falls of up to 10-feet, 3-inches to the concrete surface below while accessing a job made portable ladder which did not extend at least 3 feet past the second floor landing to allow employees safe access.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1926.416 E01

Other-than-serious 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used:  (a) Front side, new residential construction located at 1 Hollow Way, Newnan, GA 30265: The employer failed to inspect and remove a 50 ft. 14 gauge flexible cord which had a torn and worn casing which exposed the internal circuits. This cord was used to power a Makita (Model - 5007F) 7-1/4-inch Circular Saw which was double insulated and plugged into a GFCI outlet.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340489186.