Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: JACKY'S ROPA USADA, LLC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of JACKY'S ROPA USADA, LLC. in 401 CHIHUAHUA STREET STE. #4, LAREDO, TX 78040 (NAICS 493110). OSHA activity number 340498070.

Watch Jacky'S Ropa Usada, LLC. — free Get an email when a new federal OSHA severe-injury report for Jacky'S Ropa Usada, LLC. is published. One employer, no account, unsubscribe in one click.
Site address
401 CHIHUAHUA STREET STE. #4
City
LAREDO
State
TX
ZIP
78040
Mailing
401 CHIHUAHUA STREET STE. #4, LAREDO, TX 78040
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
493110
Employees
22
Ownership type
A

6 citations on file for this inspection.

1910.22 A01

Serious Gravity 5 1 instance 20 exposed
Issued
Penalty
Initial $2400.00 · Current $2400.00
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition.  At the west wall of the warehouse employees were exposed to hazards as the female restroom toilet had a broken lid, exposing employees to impalement hazards.
Recent events (1)
  • — Z (S) $2400

1910.37 A03

Serious Gravity 10 1 instance 20 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed:  At the west wall of the warehouse employees were exposed to hazards as bay doors were blocked and gated preventing employees having an unobstructed egress route in case of an emergency.
Recent events (1)
  • — Z (S) $2800

1910.157 C01

Serious Gravity 10 1 instance 20 exposed
Issued
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:  At the west wall of the warehouse employees were exposed to hazards as portable fire extinguishers had obstructed access due to clothing piles and clothing in boxes blocking access.
Recent events (1)
  • — Z (S) $2800

1910.303 F02

Serious Gravity 5 1 instance 20 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $2000.00
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:  At the south west corner wall of the warehouse employees were exposed to electrocution hazards as a disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident.
Recent events (1)
  • — Z (S) $2000

1910.305 B02 I

Serious Gravity 5 1 instance 20 exposed
Issued
Penalty
Initial $2000.00 · Current $2000.00
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy:  At the west wall of the warehouse employees were exposed to electrocution hazards as a electrical outlet was not covered to prevent accidental contact with energized parts.
Recent events (1)
  • — Z (S) $2000

1910.305 G02 II

Serious Gravity 10 1 instance 20 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1910.305(g)(2)(ii): Flexible cords were not used in continuous lengths without splice or tap:  At the west wall of the warehouse employees were exposed to electrocution hazards as a flexible cord was spliced and repaired with a different type of cord this repair was covered with black, electrical tape. The cord conducted power for a wall mounted fan.
Recent events (1)
  • — Z (S) $2800

SPEEDX

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340498070.