Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: EXTREME STAFFING OF IDAHO

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of EXTREME STAFFING OF IDAHO in 621 BLUE LAKES BLVD N, TWIN FALLS, ID 83301 (NAICS 561320). OSHA activity number 340504356.

Watch Extreme Staffing OF Idaho — free Get an email when a new federal OSHA severe-injury report for Extreme Staffing OF Idaho is published. One employer, no account, unsubscribe in one click.
Site address
621 BLUE LAKES BLVD N
City
TWIN FALLS
State
ID
ZIP
83301
Mailing
P.O. BOX 6072, TWIN FALLS, ID 83303
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
561320
Employees
2000
Ownership type
A

2 citations on file for this inspection.

1910.147 C06 I

Deleted Serious Gravity 10 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $7000.00 · Current $0.00 Reduced
29 CFR  1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.  a) On or about March 30, 2015 or prior thereto: Quality Truss & Lumber, Inc. had not conducted a periodic inspection of energy control procedures in the workplace.  Lockout is performed on such equipment as the 240 Volt Spida 2000 Saws.  Temporary labor of Extreme Staffing of Idaho utilize these saws during truss manufacturing.  Abatement certification and documentation is required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $7000

1910.213 H01

Serious Gravity 10 2 instances 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $3500.00
29 CFR 1910.213(h)(1):   The sides of the lower exposed portion of the blade were not guarded to the full diameter of the blade by a device that will automatically adjust itself to the thickness of the stock and remain in contact with stock being cut to give maximum protection possible for the operation being performed.  a) On or about March 30, 2015 or prior thereto:  The lower portion of Spida Saw #1 was not guarded to prevent contact with the saw during truss manufacturing.  b) On or about March 30, 2015 or prior thereto:  The lower portion of Spida Saw #3 was not guarded to prevent contact with the saw during truss manufacturing.  Abatement certification and documentation is required for this item.
Recent events (2)
  • — I (S) $3500
  • — Z (S) $0

View EXTREME STAFFING OF IDAHO's full OSHA safety record →