Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: PENN CARBOSE INC.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of PENN CARBOSE INC. in 100 BURGESS STREET, SOMERSET, PA 15501 (NAICS 325180). OSHA activity number 340505734.

Watch Penn Carbose INC. — free Get an email when a new federal OSHA severe-injury report for Penn Carbose INC. is published. One employer, no account, unsubscribe in one click.
Establishment
PENN CARBOSE INC.
Site address
100 BURGESS STREET
City
SOMERSET
State
PA
ZIP
15501
Mailing
100 BURGESS STREET, SOMERSET, PA 15501
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325180
Employees
10
Ownership type
A

10 citations on file for this inspection.

1910.22 A02

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $950.00 Reduced
29 CFR 1910.22(a)(2): The floors of every workroom were not maintained in a clean condition:    a) At the Facility, on or about April 1, 2015 - Accumulations of combustible carbose dust generated during grinding operations had settled on the floor areas and equipment surfaces.
Recent events (2)
  • — I (S) $950
  • — Z (S) $1200

1910.23 C01

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $950.00 Reduced
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent):    a)  In the hammer mill area, on or about April 1, 2015 - An employee working on a platform was exposed to a fall hazard of approximately 8 feet.    b) In the pit area, on or about April 1, 2015 -  An employee walking on a caustic tank to check fluid levels was exposed to a fall hazard of approximately 11 feet.
Recent events (2)
  • — I (S) $950
  • — Z (S) $1200

1910.23 C03

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $950.00 Reduced
29 CFR 1910.23(c)(3): Regardless of height, open-sided floors, walkways, platforms, or runways above or adjacent to dangerous equipment, pickling or galvanizing tanks, degreasing units, and similar hazards were not guarded with a standard railing and toe board:    a)  In the acid pit area, on or about April 1, 2015 - The area around the pit was not guarded with a standard railing and toe board to guard against employees falling into an acid and water pit.
Recent events (2)
  • — I (S) $950
  • — Z (S) $1200

1910.134 C01

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $950.00 Reduced
29 CFR 1910.134(c)(1): The employer did not establish and implement a written respiratory protection program with worksite-specific procedures in any workplace where respirators are necessary to protect the health of the employee or whenever respirators are required by the employer:    a)  At the facility, on or about April 1, 2015 - A written respiratory protection program was not established and implemented were respirators were required.  An employee is required to wear a North 7700 Series half-mask respirator when working with acids.
Recent events (2)
  • — I (S) $950
  • — Z (S) $1200

1910.134 E01

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(e)(1):  The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:    a)  At the facility, on or about April 1, 2015 - Medical Evaluations were not provided to employees before they were required to wear a respirator.  Employee are required to wear North Series 7700 half-mask respirator when working with acids.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 F01

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(f)(1): The employer did not ensure that employees using a tight-fitting facepiece respirator pass an appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT) as stated in this paragraph:    a)  At the facility, on or about April 1, 2015 - A fit test was not provided to employees who were required to wear a respirator.  An employee are required to wear North Series 7700 half-mask respirator when working with acids.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 H01

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $0.00 Reduced
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:    a) At the facility, on or about April 1, 2015 - Employees who were exposed the carbose dust, a combustible, were not provided with effective information and training.
Recent events (2)
  • — I (O) $0
  • — Z (S) $1200

1910.1200 H03 IV

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(h)(3)(iv):   The details of the hazard communication program developed by the employer, did not include an explanation of the labels received on shipped containers and the workplace labeling system used by their employer; the safety data sheet, including the order of information and how employee could obtain and use the appropriate hazard information:    a)  At the facility, on or about April 1, 2015 - Employees were not provided with training in regards to the new labeling element and safety data sheets.  Employees are exposed to acetic acid, a flammable material.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 C02 I

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible:  a)  At the facility, on or about April 1, 2015 - Employees, who voluntary wear N-95 particulate dusk mask respirators, were not provided with the information contained in Appendix D to 29 CFR 1910.134.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.145 C03

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00

Hazardous substances E200

29 CFR 1910.145(c)(3): Safety instruction sign(s) were not used where there was a need for general instructions and suggestions relative to safety measure(s):  a) At the facility, on or about April 1, 2015 - Safety instruction signs were not used in areas where combustible carbose dust was generated during grinding operations were present.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340505734.