Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: JUAN OSORIO CARPENTRY

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JUAN OSORIO CARPENTRY in 10 OLD RIVERHEAD RD., RIVERHEAD, NY 11901 (NAICS 238130). OSHA activity number 340506682.

Watch Juan Osorio Carpentry — free Get an email when a new federal OSHA severe-injury report for Juan Osorio Carpentry is published. One employer, no account, unsubscribe in one click.
Site address
10 OLD RIVERHEAD RD.
City
RIVERHEAD
State
NY
ZIP
11901
Mailing
644-A ENT AVE., WESTHAMPTON, NY 11977
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
6
Ownership type
A

4 citations on file for this inspection.

1926.102 A01

Serious Gravity 5 2 instances 3 exposed
Issued
Penalty
Initial $1600.00 · Current $1600.00
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents  a) Worksite, 10 Old Riverhead Rd., Riverhead, NY- Employee in front section of roof was using a pneumatic nail gun to install roofing shingles was not wearing eye protection; on or about 4/1/15.  b) Worksite, 10 Old Riverhead Rd., Riverhead, NY- Employees in back section of the roof were using pneumatic nail guns to frame a soffit were not wearing eye protection; on or about 4/1/15.   Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19.
Recent events (1)
  • — Z (S) $1600

1926.501 B11

Serious Gravity 10 2 instances 3 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems:  Instance a) Worksite, 10 Old Riverhead Rd., Riverhead- Employee in front section of the roof was observed working on a 5/12 pitch at a height of approximately 20 feet while not protected from falling by the use of guardrail, safety net or personal fall arrest systems; on or about 4/1/15.  Instance b) Worksite, 10 Old Riverhead Rd., Riverhead- Two employees in back section of the roof were observed working on a 5/12 pitch at a height of approximately 12 feet while not protected from falling by the use of guardrail, safety net or personal fall arrest systems; on or about 4/1/15.  Note:  In addition to abatement certification the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19.
Recent events (1)
  • — Z (S) $2800

1926.1053 B01

Serious Gravity 5 1 instance 3 exposed
Issued
Penalty
Initial $2000.00 · Current $2000.00
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access:  Instance a) Worksite, 10 Old Riverhead Rd., Riverhead- Employees were observed climbing an extension ladder to access the roof in the back of the building. The side rails extended approximately 20" above the landing; on or about 4/1/15.   Note:   Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19.
Recent events (1)
  • — Z (S) $2000

1926.1053 B04

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $2000.00 · Current $2000.00
29 CFR 1926.1053(b)(4): Ladders were used for purposes other than the purposes for which they were designed:  Instance a) Worksite, 10 Old Riverhead Rd., Riverhead, NY- An A-frame step ladder was being used on the roof in the closed position to access a roof soffit; on or about 4/1/15.  Note:   Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19.