Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: EASTERN REMODELING CO.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of EASTERN REMODELING CO. in CENTER STREET AND PROSPECT AVENUE, EAST AURORA, NY 14052 (NAICS 236118). OSHA activity number 340509868.

Watch Eastern Remodeling CO. — free Get an email when a new federal OSHA severe-injury report for Eastern Remodeling CO. is published. One employer, no account, unsubscribe in one click.
Site address
CENTER STREET AND PROSPECT AVENUE
City
EAST AURORA
State
NY
ZIP
14052
Mailing
165 LASALLE AVENUE, KENMORE, NY 14217
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236118
Employees
9
Ownership type
A

5 citations on file for this inspection.

1926.100 A

Serious Gravity 1 1 instance 3 exposed
Issued
Penalty
Initial $1200.00 · Current $600.00 Reduced
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets:    a) On or about 4/1/15 at a roof replacement project located at the corner of Center Street and Prospect Avenue, East Aurora, New York; employees working on the ground below active roof operations were not wearing hard hats.    NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $600
  • — Z (S) $1200

1926.451 E01

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $1600.00 · Current $800.00 Reduced
29 CFR 1926.451(e)(1): A means of access for scaffold platforms more than 2 feet (0.6 m) above or below a point of access, such as portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface was not used:    a) On or about 4/1/15 at a roof replacement project located at the corner of Center Street and Prospect Avenue, East Aurora, New York; employees were using a ladder jack scaffold, with the scaffold brackets and platform to the outside of the supporting ladders. The employees had to access the platform by climbing the supporting ladders and climbing around the bracket and platform.    NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $800
  • — Z (S) $1600

1926.451 G01 I

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $2000.00 · Current $1000.00 Reduced
29 CFR 1926.451(g)(1)(i): Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold was not protected by a personal fall arrest system:    a) On or about 4/1/15 at a roof replacement project located at the corner of Center Street and Prospect Avenue, East Aurora, New York; employees were using a ladder jack scaffold to perform work and access the roof. The platform height was approximately 12 to 20 feet and there was no personal fall arrest system in place.    NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1926.501 B11

Serious Gravity 5 1 instance 9 exposed
Issued
Penalty
Initial $2000.00 · Current $1000.00 Reduced
29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems:    a) On or about 4/1/15 at a roof replacement project located at the corner of Center Street and Prospect Avenue, East Aurora, New York; employees were tearing shingles off from a roof with a 12 in 12 pitch and 18 in 12 pitch with an eave height of approximately 20 feet. There were no fall protection systems in place.    NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1926.1053 B01

Serious Gravity 5 1 instance 9 exposed
Issued
Penalty
Initial $2000.00 · Current $1000.00 Reduced
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:    a) On or about 4/1/15 at a roof replacement project located at the corner of Center Street and Prospect Avenue, East Aurora, New York; employees were accessing a roof from the rear of the house using extension ladders that had there side rails approximately 18 inches above the landing surface.    NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340509868.