HERMITAGE, PA —
OSHA Inspection: PITZULO BROTHERS COMPANY, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PITZULO BROTHERS COMPANY, INC. in 240 NORTH HERMITAGE ROAD, HERMITAGE, PA 16148 (NAICS 238160). OSHA activity number 340514603.
Where did this inspection happen?
- Establishment
- PITZULO BROTHERS COMPANY, INC.
- Site address
- 240 NORTH HERMITAGE ROAD
- City
- HERMITAGE
- State
- PA
- ZIP
- 16148
- Mailing
- 7680 BROOKSTONE PLACE, YOUNGSTOWN, OH 44514
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 5
- Ownership type
- A
Citations
9 citations on file for this inspection.
1926.252 A
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1926.252(a): An enclosed chute of wood, or equivalent material, was not used where materials were dropped more than 20 feet to points lying outside the exterior walls of the building(s): A.) Pitzulo Brothers Company, Inc., 240 North Hermitage Road, Hermitage, PA 16148, south side of the structure, on or about April 1, 2015 and times prior thereto: Employees were throwing roofing materials including, but not limited to, shingles, from the roof and allowing the material to free fall 27-feet to the ground below. A chute was not in place to direct the materials from the roof to the ground.
Recent events (2)
- — I (S) $1000
- — Z (S) $1600
1926.100 A
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: A.) Pitzulo Brothers Company, Inc., 240 North Hermitage Road, Hermitage, PA 16148, south side of the structure, on or about April 1, 2015 and times prior thereto: Employees were throwing roofing materials including, but not limited to, shingles, from the roof and allowing the material to free fall 27-feet to the ground below. Employees at ground level were not wearing head protection.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.404 B01 I
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites: A.) Pitzulo Brothers Company, Inc., 240 North Hermitage Road, Hermitage, PA 16148, south side of the structure, on or about April 1, 2015 and times prior thereto: Employees were utilizing a Rolair Systems air compressor unit (M/N: VT25BIG, S/N: 11121785) to operate a pneumatic nailer for activities including, but not limited to, roofing operations. The air compressor was not plugged into a ground-fault circuit interrupter. The company was not utilizing an assured equipment grounding program.
Recent events (2)
- — I (S) $1000
- — Z (S) $1600
1926.21 B02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe condition(s) and the regulation(s) applicable to his work environment to control or eliminate any hazard(s) or other exposure to illness or injury: A.) Pitzulo Brothers Company, Inc., 240 North Hermitage Road, Hermitage, PA 16148, on or about April 1, 2015 and times prior thereto: Employees were utilizing electrical equipment including, but not limited to, a Rolair Systems air compressor unit (M/N: VT25BIG, S/N: 11121785). Employees had not recieved electrical safety training on items including but not limited to extesion cord inspection/safety requirements and ground fault circuit interrupters. B.) Pitzulo Brothers Company, Inc., 240 North Hermitage Road, Hermitage, PA 16148, on or about April 1, 2015 and times prior thereto: Employees were utilizing personal protective equipment including, but not limited to, safety glasses. Employees were also exposed to potential head injury hazards and were not wearing hard harts. Employees did not have personal protective equipment (PPE) training on items that included but were not limited to the required use of of PPE, when to use the PPE, and the care and mainteance of the PPE.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.501 B11
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $2000.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: A.) Pitzulo Brothers Company, Inc., 240 North Hermitage Road, Hermitage, PA 16148, on or about April 1, 2015 and times prior thereto: Employees engaged in roof activities including, but not limited to, re-shingling operations, were exposed to a fall hazard of 27-feet to the ground below. The employees were not utilizing a means or method of fall protection including, but not limited to, guardrail systems with toeboards, safety net systems, or personal fall arrest systems. B.) Pitzulo Brothers Company, Inc., 240 North Hermitage Road, Hermitage, PA 16148, on or about April 1, 2015 and times prior thereto: Employees engaged in roof activities including, but not limited to, re-shingling operations, were exposed to a fall hazard of 16-feet to a lower roof below. The employees were not utilizing a means or method of fall protection including, but not limited to, guardrail systems with toeboards, safety net systems, or personal fall arrest systems.
Recent events (2)
- — I (S) $2000
- — Z (S) $2800
1926.501 B01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface having an unprotected side or edge which was six or more feet (1.8m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: A.) Pitzulo Brothers Company, Inc., 240 North Hermitage Road, Hermitage, PA 16148, on or about April 1, 2015 and times prior thereto: Employees were standing on the lower roof of the structure to raise the flyer section of a Werner Craft-Master metal extension ladder (M/N: D1540-2) to the upper roof above. Employees were exposed to a fall hazard of 11-feet to the ground below. The employees were not utilizing a means or method of fall protection including, but not limited to, guardrail systems, safety net systems, or personal fall arrest systems.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.503 A01
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $400.00 Reduced
General-duty citation text
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: A.) Pitzulo Brothers Company, Inc., 240 North Hermitage Road, Hermitage, PA 16148, on or about April 1, 2015 and times prior thereto: Employees did not have fall protection training. Employees were potentially exposed to fall hazards from roofing work and related job tasks.
Recent events (2)
- — I (S) $400
- — Z (S) $2000
1926.503 B01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.503(b)(1): The employer did not verify fall protection training by preparing a written certification record: A.) Pitzulo Brothers Company, Inc., 240 North Hermitage Road, Hermitage, PA 16148, on or about April 1, 2015 and times prior thereto: An employee had fall protection training through a previous employer. A determination was not conducted to ascertain if the employee's previous fall protection training was adequate. In addition, a written certification record was not prepared for the employee' s previous fall protection training.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1060 A
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1060(a): The employer did not provide a training program for each employee using ladders and stairways, as necessary, which would enable each employee to recognize hazards related to ladders and stairways and train each employee in the procedures to be followed to minimize these hazards: A.) Pitzulo Brothers Company, Inc., 240 North Hermitage Road, Hermitage, PA 16148, on or about April 1, 2015 and times prior thereto: Employees utilizing a Werner Craft-Master metal extension ladder (M/N: D1540-2) did not have ladder safety training.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 238160)
SIOUX FALLS, SD—2026-07-13
H & R ROOFING OF SOUTH DAKOTA, INC.
HENDERSON, NV—2026-07-13
INTEGRITY ROOFING LLC
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CAMDEN, OH—2026-07-13
ALBERTO MORALES
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR
More inspections in PA
MILTON, PA—2026-07-10
HOMETOWN FOODS CHEF BOYARDEE CO.
SUNBURY, PA—2026-07-10
DEMPSEY UNIFORM & LINEN SUPPLY, INC
LANDISVILLE, PA—2026-07-10
FAIRVIEW DEMOLITION LLC
YORK, PA—2026-07-10
AMERICAN SPECIALTY SYSTEMS INC.
WILLIAMSPORT, PA—2026-07-10
INTERNATIONAL PAINT PROS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340514603.