Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: WADE TRANSPORT, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of WADE TRANSPORT, INC. in 2742 HIGHWAY 49 NORTH, COLLINS, MS 39428 (NAICS 484110). OSHA activity number 340515113.

Watch Wade Transport, INC. — free Get an email when a new federal OSHA severe-injury report for Wade Transport, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2742 HIGHWAY 49 NORTH
City
COLLINS
State
MS
ZIP
39428
Mailing
P.O. BOX 1930, COLLINS, MS 39428
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
484110
Employees
43
Ownership type
A

6 citations on file for this inspection.

1910.106 B02 VII A

Serious Gravity 5 1 instance 7 exposed
Issued
Abate by
Penalty
Initial $2100.00 · Current $1260.00 Reduced
29 CFR 1910.106(b)(2)(vii)(a): "Drainage and diked areas."  Area(s) surrounding tank(s) containing flammable or combustible liquids were not provided with adequate drainage or dikes:    (a) South of Office Building - On or about April 3, 2015 employees were exposed to the ignition of spillage from the 12-14,000 gallon capacity above ground diesel fuel storage tank due to the absence of an earthen dike or proper drainage away from adjoining property or waterways.
Recent events (2)
  • — I (S) $1260
  • — Z (S) $2100

1910.106 D05 III

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.106(d)(5)(iii): The storage of flammable or combustible liquids required and used for the maintenance and operation of building and operation of equipment was not kept in closed metal containers stored in a storage cabinet or in safety cans or in an inside storage room not having a door that opens into that portion of the building used by the public:  (a)  Mechanic's Shop, Parts Room - On or about April 3, 2015 employees were exposed to the ignition of flammable aerosol paint products stored on an open 3-tiered metal shelving unit and elsewhere due to there being no approved storage cabinet for the following products:  multiple Krylon Rust Preventative 12 ounce aerosol cans; 17 ounce cans of IPC Light Gray Primer; cans of NAPA Disc Brake Quiet; cans of Krylon Farm & Implement Paint; cans of Krylon Rust Tough Rust Preventative Enamel; a gallon of Nason 491-17 ETCH Primer, cans of brake cleaner, penetrating oil, starting fluid, penetrating grease, etc.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.22 D01

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.22(d)(1): In every building or other structure, or part thereof, used for mercantile, business, industrial or storage purposes, the loads approved by the building official were not marked on plates of approved design and securely affixed in a conspicuous place in each space to which they relate.  (a) Mechanics Shop, Above Parts Room - On or about April 3, 2015 load rating was not posted on 16 foot by 40 foot overhead storage area above the parts room.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.24 H

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.24(h): Handrails were not provided on at least one side of closed stairways preferably on the right side descending:  (a)  Mechanics Shop, Parts Room - On or about April 3, 2015, employees were exposed to falls due to the absence of any standard stair handrail on the 47 1/4 inch wide enclosed wooden stairs with 15 risers. Stairs leading to/from overhead storage area above Parts Room did not have stair handrail.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.253 B04 III

Other-than-serious 1 instance 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00

Hazardous substances 007002400530X100

29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour:  (a) Mechanics Shop, Parts Room - On or about April 3, 2015 employees were exposed to an Airgas Oxygen cylinder being stored next to a short black acetylene cylinder.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 F06

Other-than-serious 1 instance 7 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00

Hazardous substances D150

29 CFR 1910.1200(f)(6): Workplace labeling.  Except as provided in paragraphs (f)(7) and (f)(8) of this section, the employer did not ensure that each container of hazardous chemicals in the workplace is labeled, tagged or marked with either:  (i) The information specified under paragraphs (f)(1)(I) through (v) of this section for labels on shipped containers; or,  (ii) Product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals, and which, in conjunction with the other information immediately available to employees under hazard communication program, will provide employees with the specific information regarding the physical and health hazards of the hazardous chemical.  (a) South of Office Building - On or about April 3, 2015, employees were exposed to injury from spillage from the 12-14,000 gallon capacity above ground Diesel Fuel Storage Tank due to the absence of information about the tank's contents and appropriate hazard warning(s), e.g., "DIESEL" and "COMBUSTIBLE."
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340515113.