RIVERVIEW, FL —
OSHA Inspection: JESSIE'S CONSTRUCTION, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of JESSIE'S CONSTRUCTION, INC. in 13832 MOONSTONE CANYON DR, RIVERVIEW, FL 33579 (NAICS 238140). OSHA activity number 340529205.
Where did this inspection happen?
- Establishment
- JESSIE'S CONSTRUCTION, INC.
- Site address
- 13832 MOONSTONE CANYON DR
- City
- RIVERVIEW
- State
- FL
- ZIP
- 33579
- Mailing
- 1214 NOSLEDA STREET, PLANT CITY, FL 33563
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 6
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.451 B01
- Issued
- Penalty
- Initial $1700.00 · Current $1700.00
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): a. Along the exterior wall, the single tier fabricated frame scaffolding was not fully planked, exposing employees to a 5 foot fall hazard, on or about 04/09/2015.
Recent events (1)
- — Z (S) $1700
1926.451 C03
- Issued
- Penalty
- Initial $1700.00 · Current $1700.00
General-duty citation text
29 CFR 1926.451(c)(3): Supported scaffold poles, legs, posts, frames, and uprights were not plumb and braced to prevent swaying and displacement: a. Along the exterior wall, single tier fabricated frame scaffolding was not braced, exposing employees to a 5 foot fall hazard, on or about 04/09/2015.
Recent events (1)
- — Z (S) $1700
1926.451 E06 VI
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $2000.00
General-duty citation text
29 CFR 1926.451(e)(6)(vi): Integral prefabricated scaffold access frames shall have a maximum spacing between rungs of 16 3/4 inches (43 cm): a. Along the exterior wall, single tier prefabricated frame scaffolding with rungs spaced 20 inches apart were used by employees as a ladder to gain access to the working level of the scaffolding, exposing the employees to 5 foot fall hazard, on or about 04/09/2015.
Recent events (1)
- — Z (S) $2000
1910.134 D01 III
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.134(d)(1)(iii): The employer did not identify and evaluate the respiratory hazard(s) in the workplace; including a reasonable estimate of employee exposures to respiratory hazards and identification of the contaminant's chemical state and physical form: a. Near the rear exterior wall, the employer did not evaluate the respiratory hazards that come from cutting concrete blocks with a STIHL TS420 concrete saw, exposing employees to silica dust and possible respiratory illnesses, on or about 04/09/2015.
Recent events (1)
- — Z (O) $0
1926.102 A01
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: a. Near the rear of the exterior wall, eye protection was not provided to the operators of a STIHL TS-420 CutQuik concrete saw, exposing employees to the hazard of struck-by, on or about 04/09/2015. b. Near the scaffolding, eye protection was not provided to the employees using hammers to split concrete blocks, exposing employees to the hazard of struck-by, on or about 04/09/2015.
Recent events (1)
- — Z (O) $0
1926.454 B02
- Issued
- Abate by
- Penalty
- Initial $400.00 · Current $400.00
General-duty citation text
29 CFR 1926.454(b)(2): The employer did not have each employee who was involved in erecting, disassembling, moving, operating, repairing, maintaining, or inspecting a scaffold trained by a competent person to recognize any hazards associated with the correct procedures for erecting, disassembling, moving, operating, repairing, inspecting, and maintaining the type of scaffold in question: a. Along the exterior wall, employees erected, disassembled, and worked from scaffolding without being trained on the hazards associated with scaffolding, exposing the employees to a 5 foot fall hazard, on or about 04/09/2015.
Recent events (1)
- — Z (O) $400
More inspections in this industry (NAICS 238140)
RENO, NV—2026-07-16
DC MASONRY
WINNETKA, IL—2026-07-15
CHICAGO STUCCO CO.
LODI, NJ—2026-07-15
J & O MASONRY CONTRACTORS
DORAVILLE, GA—2026-07-14
SUDLOW CONCRETE, INC.
FLAGLER BEACH, FL—2026-07-14
PLANET DESIGN SERVICES, INC.
More inspections in FL
MARIANNA, FL—2026-07-16
BRANNON BROTHERS CONSTRUCTION, LLC
LAKELAND, FL—2026-07-16
SOUTHERN MILLING & LUMBER, INC.
OAKLAND PARK, FL—2026-07-16
PKB CABINETRY
LAKELAND, FL—2026-07-16
ELIJAH WHOLESALE, LLC.
TAMPA, FL—2026-07-16
VALENCIA WHOLESALE, INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340529205.