SAINT PETERS, MO —
OSHA Inspection: WAINWRIGHT A DIVISION OF MODINEER
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of WAINWRIGHT A DIVISION OF MODINEER in 17 CERMAK BLVD., SAINT PETERS, MO 63376 (NAICS 336399). OSHA activity number 340535764.
Where did this inspection happen?
- Establishment
- WAINWRIGHT A DIVISION OF MODINEER
- Site address
- 17 CERMAK BLVD.
- City
- SAINT PETERS
- State
- MO
- ZIP
- 63376
- Mailing
- 17 CERMAK BLVD., SAINT PETERS, MO 63376
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336399
- Employees
- 160
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.147 C04 II B
- Issued
- Abate by
- Penalty
- Initial $2550.00 · Current $1785.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy: a. The machine specific lockout procedures did not document how stored pneumatic energy was to be released after energy source isolation, such as with equipment that retained airline pressure after lockout of the energy source. Abatement documentation is required for this violation.
Recent events (2)
- — I (S) $1785
- — Z (S) $2550
1910.147 C04 II D
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(D): The energy control procedures did not clearly and specifically outline the requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control: a. The machine specific lockout procedures did not document how to test machines for energy isolation after application of a lock on the machine. Abatement documentation is required for this violation.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.178 L03 I K
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.178(l)(3)(i)(K): 29 CFR 1910.178(l)(3)(i)(K): Powered industrial truck operators did not receive training on refueling: a. Forklift operators did not receive training on how to correctly align propane tanks on the forklift; propane tank pin alignment opening was not aligned on the pin (pin was not present on all trucks). Abatement documentation is required for this violation.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.178 P01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition(s): a. Some forklifts were operated with the propane tank not correctly aligned on the pin (pin was not present on all trucks). Abatement documentation is required for this violation.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 336399)
HATTON, KY—2026-06-16
69227 - TOPY AMERICA INC
GEORGETOWN, KY—2026-06-11
69204 - VUTEQ USA INC
CLACKAMAS, OR—2026-05-21
317744130 - WARN INDUSTRIES INC
WOODBINE, KY—2026-05-19
69127 - CTA ACOUSTICS INC
DAMASCUS, OR—2026-04-22
317743801 - DOC RACE LLC
More inspections in MO
CLINTON, MO—2026-07-14
TORCHYLO BUILDERS, LLC.
KANSAS CITY, MO—2026-07-09
NIAGARA BOTTLING
MONETT, MO—2026-07-09
MONETT METALS INC.
PARKVILLE, MO—2026-07-08
SKY-TECH ROOFING, LLC.
SPRINGFIELD, MO—2026-07-07
D & C CONSTRUCTION, LLC.
Source