BUFORD, GA —
OSHA Inspection: DISPLAY IT, INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of DISPLAY IT, INC. in 4907 GOLDEN PKWY, BUFORD, GA 30518 (NAICS 337215). OSHA activity number 340556034.
Where did this inspection happen?
- Establishment
- DISPLAY IT, INC.
- Site address
- 4907 GOLDEN PKWY
- City
- BUFORD
- State
- GA
- ZIP
- 30518
- Mailing
- 4907 GOLDEN PKWY, BUFORD, GA 30518
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 337215
- Employees
- 46
- Ownership type
- A
Citations
11 citations on file for this inspection.
1910.107 B05 I
- Issued
- Abate by
- Penalty
- Initial $2380.00 · Current $1428.00 Reduced
General-duty citation text
29 CFR 1910.107(b)(5)(i): The spraying operations was not designed, installed or maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute Display It, Inc., Buford, GA - In the fabrication department, employee(s) were spraying flammable adhesive in the spray booth. The average air velocity over the open face of the booth was less than 100 feet per minute (fpm). The air velocity on the lower portion of the booth, where the spraying occurred, measured to be less than 20 fmp, on or about 4/15/15.
Recent events (2)
- — I (S) $1428
- — Z (S) $2380
1910.107 C06
- Issued
- Abate by
- Penalty
- Initial $1785.00 · Current $1071.00 Reduced
General-duty citation text
29 CFR 1910.107(c)(6): Electrical wiring, motors, and other equipment outside of but within twenty (20) feet of any spray area, and not separated therefrom by partitions, produced sparks under normal operating conditions and did not otherwise conform to the provisions of subpart S of this part for Class I, Division 2 Hazardous Locations: a) Display It, Inc., Buford, GA - In the fabrication department, employee(s) were spraying flammable adhesive in the spray booth. An electric router used at approximately 12 feet of the spraying operation was not Class I, Division 2, on or about 4/15/15. b) Display It, Inc., Buford, GA - In the fabrication department, employee(s) were spraying flammable adhesive in the spray booth. An electric outlet used at the cramper located approximately 54 inches of the spraying operation was not Class I, Division 2, on or about 4/15/15.
Recent events (2)
- — I (S) $1071
- — Z (S) $1785
1910.134 C01
- Issued
- Abate by
- Penalty
- Initial $1785.00 · Current $1071.00 Reduced
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: Display It, Inc., Buford, GA - In the fabrication department, employee(s) spraying flammable adhesive were required to wear a 3M half mask, negative pressure respirator with organic vapors cartridges. A written respiratory protection program was not developed, on or about 4/15/15.
Recent events (2)
- — I (S) $1071
- — Z (S) $1785
1910.134 E01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: The employer may discontinue an employee's medical evaluations when the employee is no longer required to use a respirator. Display It, Inc., Buford, GA - In the fabrication department, employee(s) spraying flammable adhesive were required to wear a 3M half mask, negative pressure respirator with organic vapors cartridges. Medical evaluations were not provided, on or about 4/15/15.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 F01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): Display It, Inc., Buford, GA - In the fabrication department, employee(s) spraying flammable adhesive were required to wear a 3M half mask, negative pressure respirator with organic vapors cartridges. Fit testing was not conducted, on or about 4/15/15.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 K01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.134(k)(1): The employer did not provide effective training that covered the required elements in 1910.134(k)(1)(i) through 1910.134(k)(1)(vii): Display It, Inc., Buford, GA - In the fabrication department, employee(s) spraying flammable adhesive were required to wear a 3M half mask, negative pressure respirator with organic vapors cartridges. Respirator training as required by the standard was not provided, on or about 4/15/15.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A03 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): Display It, Inc., Buford, GA - In the production department, employees used the red chop saw to cut card board. The lower portion of the blade was not guarded, on or about 4/15/15.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 E01
- Issued
- Abate by
- Penalty
- Initial $2975.00 · Current $1785.00 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: Display It, Inc., Buford, GA - Employees handled hazardous substances, such as but not limited to, flammable adhesive containing acetone, hard and softwood, alcohols, primer and lacquer thinner. A written hazard communication program was not developed, on or about, 4/15/15.
Recent events (2)
- — I (S) $1785
- — Z (S) $2975
1910.1200 F04
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(f)(4): The chemical manufacturer, importer, distributor, or employer did not ensure that labels or other forms of warning used for hazardous chemicals regulated by OSHA in a substance-specific health standard, were used in accordance with the requirements of that standard: Display It, Inc., Buford, GA - In the printing area, a drum containing PS-Adhesion Promoter and Ink was not labeled, on or about, 4/15/15.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 G08
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(g)(8): The employer did not ensure that material safety data sheets for each hazardous substance were readily accessible to employees in their work area during each work shift: Display It, Inc., Buford, GA - In the production areas, employees handled hazardous substances flammable adhesive containing acetone, hard and softwood. Material Safety Data Sheets (SDS) for these products were not available for review, on or about, 4/15/15.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 H01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: Display It, Inc., Buford, GA - Employees handled hazardous substances, such as but not limited to, flammable adhesive containing acetone, hard and softwood, alcohols, primer and lacquer thinner. Information and training as required by the hazard communication standard had not been provided, on or about, 4/15/15.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at DISPLAY IT, INC.
FOOTHILL RANCH, CA—2011-06-06 00:00:00
DISPLAY-IT INC
FOOTHILL RANCH, CA—2010-04-28 00:00:00
DISPLAY-IT INC
View DISPLAY IT, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 337215)
KALAMAZOO, MI—2026-07-13
BORROUGHS LLC
PLACENTIA, CA—2026-07-08
ALAN LEWIS INC.
MUSKEGON, MI—2026-06-26
DYNAMIC WOOD SOLUTIONS
MUSKEGON, MI—2026-06-26
DYNAMIC WOOD SOLUTIONS
HICKORY, NC—2026-06-18
161399 - ZAGAROLI AND COMPANY
More inspections in GA
ROME, GA—2026-07-13
CAMP INDUSTRIES
SOUTH FULTON, GA—2026-07-10
REEDWICK, LLC
CONYERS, GA—2026-07-10
GOLDEN STATE FOODS
DALTON, GA—2026-07-10
ENGINEERED FLOORS, LLC
METTER, GA—2026-07-10
M.A.P.C CONSTRUCTION, LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340556034.