Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: THERMA TEK RANGE CORPORATION

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of THERMA TEK RANGE CORPORATION in 115 ROTARY DRIVE VALMONT INDUSTRIAL PARK, HAZLETON, PA 18202 (NAICS 335221). OSHA activity number 340558311.

Watch Therma TEK Range Corporation — free Get an email when a new federal OSHA severe-injury report for Therma TEK Range Corporation is published. One employer, no account, unsubscribe in one click.
Site address
115 ROTARY DRIVE VALMONT INDUSTRIAL PARK
City
HAZLETON
State
PA
ZIP
18202
Mailing
115 ROTARY DRIVE VALMONT INDUSTRIAL PARK, HAZLETON, PA 18202
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
335221
Employees
19
Ownership type
A

6 citations on file for this inspection.

1910.23 C01

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $1000.00 Reduced
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent):    a) Elevated storage areas above office structures were used as storage for light materials and non-production related items.  The edges of the roofs were not equipped with standard railings, on or about, April 15, 2015.      ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $1000
  • — Z (S) $1600

1910.110 B08 XI

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $2400.00 · Current $1900.00 Reduced

Hazardous substances 2150

29 CFR 1910.110(b)(8)(xi): Piping outside buildings may be buried, above ground, or both, but shall be well supported and protected against physical damage. Where soil conditions warrant, all piping shall be protected against corrosion. Where condensation may occur, the piping shall be pitched back to the container, or suitable means shall be provided for revaporization of the condensate.    a) West side exterior of work space, the copper tubing fuel line leading from the propane tank to the rigid piping entrance to the building was flexible to touch, subjected to ice and snow, and unsupported in its entire length which exceeded ten feet, on or about April 15, 2015.      ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $1900
  • — Z (S) $2400

1910.110 B09 VII C

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00

Hazardous substances 2150

29 CFR 1910.110(b)(9)(vii)(c): Hose used for gas transfer shall be approved and shall not be used where it is likely to be subjected to temperatures above 125 degrees Fahrenheit.  The hose shall be securely connected to the appliance and the use of rubber slip ends shall not be permitted.  a) LP test areas, propane gas was used to fuel appliances during testing and trial operations and slip joints were used to connect the flexible hose, on or about April 15, 2015.    ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.307 C

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $1100.00 Reduced

Hazardous substances 16402150

29 CFR 1910.307(c): Equipment, wiring methods, and installations of equipment in hazardous (classified) locations were not intrinsically safe, approved for the hazardous (classified) location, or safe for the hazardous (classified) location:    a) LP and natural gas test areas, unapproved electrical appliances including extension cords, power taps, a stereo radio, fluorescent lighting, and toaster oven, located in a Class II, Division 2 location were not intrinsically safe, approved for Class II Division 2 locations, or safe for Class II Division 2 locations, on or about April 15, 2015.    b) Natural gas test areas, metal arc welding was performed in a Class II, Division 2 location and was not intrinsically safe, approved for Class II Division 2 locations, or safe for Class II Division 2 locations, on or about April 15, 2015.      ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $1100
  • — Z (S) $1600

1910.157 G01

Other-than-serious 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00

Hazardous substances 16402150

29 CFR 1910.157(g)(1): An educational program was not provided for all employees to familiarize them with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting:    a) Employees in the facility were provided access to fire extinguishers and were expected to fight incipient stage fires and were not provided training on their use and the potential hazards of firefighting, on or about, April 15, 2015.      "ABATEMENT CERTIFICATION REQUIRED"
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.176 B

Other-than-serious 1 instance 19 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.176(b): Storage of material created a hazard:   a) Production and storage areas, pre-manufactured industrial racking was converted into shelving via the addition of solid flooring and span supports and was not labeled with new, representative maximum shelf load ratings, on or about, April 15, 2015.     ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340558311.