Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: BURKE BROTHERS BUILDERS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of BURKE BROTHERS BUILDERS, INC. in 4204 LAKE SHORE DR., DIAMOND POINT, NY 12824 (NAICS 238910). OSHA activity number 340559004.

Watch Burke Brothers Builders, INC. — free Get an email when a new federal OSHA severe-injury report for Burke Brothers Builders, INC. is published. One employer, no account, unsubscribe in one click.
Site address
4204 LAKE SHORE DR.
City
DIAMOND POINT
State
NY
ZIP
12824
Mailing
5 OLD POST RD., LAKE GEORGE, NY 12845
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238910
Employees
6
Ownership type
A

2 citations on file for this inspection.

1926.501 B10

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $2000.00 · Current $1200.00 Reduced
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system.  Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system:      a)  On or about April 15, 2015 and at times prior thereto at the job site; an employee was removing a piece of aluminum siding from the low sloped roof without the use of fall protection.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1926.1053 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $2000.00 · Current $1200.00 Reduced
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:      a) On or about April 15, 2015 and a times prior thereto at the job site; an employee used an extension ladder to access the roof of a building.  The ladder side rails only extended approximately 1' above the upper landing surface.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000