Safety Incidents OSHA Severe Injury Reports · 2015–2025
3,913,242Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: GUCH SHEET METAL AND AC INC

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of GUCH SHEET METAL AND AC INC in 3041 SE DOMINICA TERRACE VIESEL FUEL, LLC, STUART, FL 34997 (NAICS 332322). OSHA activity number 340561661.

Watch Guch Sheet Metal AND AC INC — free Get an email when a new federal OSHA severe-injury report for Guch Sheet Metal AND AC INC is published. One employer, no account, unsubscribe in one click.
Site address
3041 SE DOMINICA TERRACE VIESEL FUEL, LLC
City
STUART
State
FL
ZIP
34997
Mailing
3201 SE DOMINICA TERRACE, STUART, FL 34997
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332322
Employees
5
Ownership type
A

4 citations on file for this inspection.

1910.243 C01

Serious Gravity 5 2 instances 3 exposed
Issued
Penalty
Initial $1600.00 · Current $960.00 Reduced
29 CFR 1910.243(c)(1): Abrasive wheel(s) were used on portable grinder(s) which were not provided with safety guard(s) meeting the requirements specified in 29 CFR 1910.243(c)(1) through (c)(4):            (a):    On or about March 29, 2015, at the above addressed worksite, employees were using a DeWalt angle grinder without a guard, exposing the employees to the hazards of being struck-by broken wheel fragments in the event of failure.            (b):    On or about March 29, 2015, at the above addressed worksite, employees were using a Chicago Electric angle grinder without a guard, exposing the employees to the hazards of being struck-by broken wheel fragments in the event of failure.
Recent events (2)
  • — I (S) $960
  • — Z (S) $1600

1910.303 B02

Serious Gravity 5 3 instances 3 exposed
Issued
Penalty
Initial $1600.00 · Current $960.00 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:        (a):    On or about March 29, 2015, at the above addressed worksite, three 4-way metal gang boxes intended to be flush mounted were used at the end of cables as extension cords for a Millermatic 252 MIG Welder, exposing employees to the hazards of electrical shock and/or burns.
Recent events (2)
  • — I (S) $960
  • — Z (S) $1600

1910.305 B01 I

Serious Gravity 5 2 instances 3 exposed
Issued
Penalty
Initial $1600.00 · Current $960.00 Reduced
29 CFR 1910.305(b)(1)(i): Conductors entering cutout boxes, cabinets, or fittings were not protected from abrasions:        (a):    On or about March 29, 2015, at the above addressed worksite, cables used as extension cords for a Millermatic 252 MIG Welder and a Plasma Cutter were directly wired into two bottom openings of an outside electric cabinet, exposing employees to the hazards of electrical shock and/or burns.
Recent events (2)
  • — I (S) $960
  • — Z (S) $1600

1910.305 G02 II

Serious Gravity 5 1 instance 3 exposed
Issued
Penalty
Initial $1600.00 · Current $960.00 Reduced
29 CFR 1910.305(g)(2)(ii): Hard-service cord and junior hard-service cord No. 14 and larger were repaired by splicing, which did not retain the insulation, outer sheath properties, and usage characteristics of the cord that was spliced:        (a):    On or about March 29, 2015, at the above addressed worksite, a 50amp/250volt plug was sliced onto the end of a hard-service cord with electrical tape and connected to a 4-way metal gang box, exposing employees to the hazards of electrical shock and/or burns.
Recent events (2)
  • — I (S) $960
  • — Z (S) $1600

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340561661.