DAMIANSVILLE, IL —
OSHA Inspection: CENTRAL TANK COATINGS, INC.
Federal Agency inspection · Safety discipline
At a glance
On , OSHA opened a federal Agency safety inspection of CENTRAL TANK COATINGS, INC. in W MAIN STREET & PARISH, DAMIANSVILLE, IL 62215 (NAICS 238320). OSHA activity number 340588771.
Where did this inspection happen?
- Establishment
- CENTRAL TANK COATINGS, INC.
- Site address
- W MAIN STREET & PARISH
- City
- DAMIANSVILLE
- State
- IL
- ZIP
- 62215
- Mailing
- 22528 CANOE RD, ELGIN, IA 52141
What kind of inspection was it?
- Inspection type
- Federal Agency (M)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238320
- Employees
- 3
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.451 A04
- Issued
- Abate by
- Penalty
- Initial $7000.00 · Current $5250.00 Reduced
General-duty citation text
29 CFR 1926.451(a)(4): Each suspension rope, including connecting hardware, used on adjustable suspension scaffolds was not capable of supporting, without failure, at least 6 times the maximum intended load applied or transmitted to that rope with the scaffold: The employer did not ensure the suspension rope used on a single point adjustable suspension boatswain chair scaffold was capable of supporting, without failure, at least 6 times the maximum intended load applied or transmitted to the 5/8 inch rope.
Recent events (2)
- — I (S) $5250
- — Z (S) $7000
1926.451 D05 III
- Issued
- Abate by
- Penalty
- Initial $7000.00 · Current $5250.00 Reduced
General-duty citation text
29 CFR 1926.451(d)(5)(iii): Suspension scaffold support devices were not secured against movement by tiebacks installed at right angles to the face of the building or structure, or opposing angle tiebacks installed and secured to a structurally sound point of anchorage on the building or structure. Sound points of anchorage include structural members, but do not include standpipes, vents, other piping systems, or electrical conduit: Hooks used to support three single point suspension boatswain chair scaffolds were not secured against movement by tiebacks while employees used the scaffold to paint the exterior of an approximately 90 foot high water tower.
Recent events (2)
- — I (S) $5250
- — Z (S) $7000
1926.451 D17
- Issued
- Abate by
- Penalty
- Initial $7000.00 · Current $5250.00 Reduced
General-duty citation text
29 CFR 1926.451(d)(17): Manually operated hoists did not have a positive crank force to descend: The employer did not provide manually operated hoists which required a positive crank force to descend on three single point suspended boatswain chair scaffolds used by the employees to paint an exterior of a 90 foot high water tank.
Recent events (2)
- — I (S) $5250
- — Z (S) $7000
1926.451 G01 I
- Issued
- Abate by
- Penalty
- Initial $7000.00 · Current $5250.00 Reduced
General-duty citation text
29 CFR 1926.451(g)(1)(i): Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold was not protected by a personal fall arrest system: On or about April 27, 2015, an employee was not protected by a personal fall arrest system while working approximately 90 feet from the lower level while conducting painting operations in a single point suspended boatswain chair scaffold.
Recent events (2)
- — I (S) $5250
- — Z (S) $7000
1926.502 D20
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $2100.00 Reduced
General-duty citation text
29 CFR 1926.502(d)(20): The employer did not provide for prompt rescue of employees in the event of a fall or did not assure that employees were able to rescue themselves: Prompt rescue of employees working with personal fall arrest systems was not provided by the employer while the employees conducted painting operation on an approximately 90 foot high water tank with the use of single point suspended boatswain chair scaffolds.
Recent events (2)
- — I (S) $2100
- — Z (S) $2800
More inspections at CENTRAL TANK COATINGS, INC.
CLEARWATER, MN—2009-09-02 00:00:00
CENTRAL TANK COATINGS INC
CLEARWATER, MN—2009-09-02 00:00:00
CENTRAL TANK COATINGS INC
View CENTRAL TANK COATINGS, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238320)
SOUTH SAN FRANCISCO, CA—2026-07-16
STELLA PAINTING INC.
GRIDLEY, CA—2026-07-15
EMPIRE PAINTING AND DECORATING INC
UNIVERSITY PLACE, WA—2026-07-15
WA317992082 - ALL SEASON PAINTING LLC
ANNAPOLIS, MD—2026-07-14
JOSE EMILIO SORTO
ANNAPOLIS, MD—2026-07-14
BLUE STAR CHESAPEAKE HOLDINGS, LLC
More inspections in IL
DEERFIELD, IL—2026-07-16
JOHN BURNS CONSTRUCTION COMPANY, LLC
BANNOCKBURN, IL—2026-07-16
BUILDER SERVICES GROUP, INC. DBA CJ INSULATION
BANNOCKBURN, IL—2026-07-16
ROOFING H.P. LLC
HIGHLAND PARK, IL—2026-07-16
UNITED PLUMBING AND DRAIN, INC.
FRANKLIN PARK, IL—2026-07-16
B & M PLASTIC INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340588771.