Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: WESTMEN BUILDERS HOME IMPROVEMENT INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of WESTMEN BUILDERS HOME IMPROVEMENT INC. in 6120 SOUTH HOWELL AVENUE, MILWAUKEE, WI 53207 (NAICS 238160). OSHA activity number 340592179.

Watch Westmen Builders Home Improvement INC. — free Get an email when a new federal OSHA severe-injury report for Westmen Builders Home Improvement INC. is published. One employer, no account, unsubscribe in one click.
Site address
6120 SOUTH HOWELL AVENUE
City
MILWAUKEE
State
WI
ZIP
53207
Mailing
10129 W FOREST HOME AVENUE #7, HALES CORNERS, WI 53130
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
4
Ownership type
A

6 citations on file for this inspection.

1910.1200 E01

Other-than-serious 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $0.00 Reduced
29 CFR 1910.1200(e)(1): Employer had not developed or implemented a written hazard communication program included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii):     (a) The employer did not develop a hazard communication program to provide employees with information on the hazardous material utilized as part of their normal work duties.
Recent events (2)
  • — I (O) $0
  • — Z (S) $1200

1910.1200 G08

Other-than-serious 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(g)(8):   The employer did not maintain in the workplace copies of the required safety data sheets for each hazardous chemical.    (a) The employer failed to ensure that Safety Data Sheets were maintained and available to employees.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.1200 H01

Other-than-serious 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:    (a) The employees were not provided with effective hazard communication training which included Safety Data Sheets, labeling, pictograms, and warning statements.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1926.20 B02

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1000.00 Reduced
29 CFR 1926.20(b)(2): The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person(s):    (a) The employer did not ensure that a worksite inspection was conducted by a competent person to ensure hazards were identified and corrected. Employees were exposed to chemical and fall hazards.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1926.503 A01

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards:    (a) The employer failed to ensure that each employee conducting roofing work on a commercial building, were trained on fall hazard and procedures or systems to use to minimize the hazards.  This exposed employees to fall hazards of approximately 14.6 feet.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.501 B10

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $850.00 Reduced
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system.  Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system.     (a) The employer failed to ensure that each employee conducting roofing work at 6120 South Howell Avenue in Milwaukee, Wisconsin, were protected from falling to the lower level by the use of a fall protection system.  This exposed employees to a fall hazard of approximately 14.6 feet.
Recent events (2)
  • — I (S) $850
  • — Z (S) $2000

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340592179.