Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: WEPFER MARINE OF HICKMAN

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of WEPFER MARINE OF HICKMAN in 380 ST. ROUTE 1354, HICKMAN, KY 42050 (NAICS 488390). OSHA activity number 340599679.

Watch Wepfer Marine OF Hickman — free Get an email when a new federal OSHA severe-injury report for Wepfer Marine OF Hickman is published. One employer, no account, unsubscribe in one click.
Site address
380 ST. ROUTE 1354
City
HICKMAN
State
KY
ZIP
42050
Mailing
PO BOX 13363, MEMPHIS, TN 38113
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
488390
Employees
3
Ownership type
A

5 citations on file for this inspection.

1910.253 B04 III

Serious Gravity 5 3 instances 4 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1800.00 Reduced
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least  (a) Wepfer Marine of Hickman - On or about 4/28/15, employees were exposed to explosion hazards when oxygen and acetylene cylinders were not separated as required.   In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $1800
  • — Z (S) $2800

1915.56 B04

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2100.00 · Current $1500.00 Reduced
29 CFR 1915.56(b)(4): Welding cable in poor condition was used.   a) Wepfer Marine of Hickman- On or about 4/28/15, employees were exposed to electrical hazards when using a welding machine with damaged cables.   In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2100

1910.106 B02 VII A

Repeat Gravity 1 2 instances 3 exposed
Issued
Abate by
Penalty
Initial $4200.00 · Current $2100.00 Reduced
29 CFR 1910.106(b)(2)(vii)(a): Area(s) surrounding tank(s) containing flammable liquids were not provided with adequate drainage or dikes:  a) Wepfer Marine of Hickman - On or about 4/28/15, above ground fuel tanks on site and did not have any drainage or diking established to protect adjacent waterways from leakage and/or spillage.   In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (R) $2100
  • — Z (R) $4200

1915.173 D

Serious Gravity 5 2 instances 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1915.173(d): Barriers or guards were not erected to prevent damage to pressure vessels, drums, and other containers of 30 gallon capacity, or over, containing flammable or toxic liquids or gases.    a) Wepfer Marine of Hickman - On or about 4/28/15, fuel tanks were not protected against collision damage from vehicles exposing employees to explosion hazards.    In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $0
  • — Z (R) $0

1910.106 D07 I B

Other-than-serious 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.106(d)(7)(i)(b): A portable fire extinguisher having a rating of not less than 12-B units was not located not less than 10 feet, nor more than 25 feet, from any Category 1, 2, or 3 flammable liquid storage area located outside of a storage room but inside a building as required.   a) Wepfer Marine of Hickman - On or about 4/28/15, a fire extinguisher was located 3 feet from fuel tanks.   In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340599679.