FAIR OAKS RANCH, TX —
OSHA Inspection: GTZ CONSTRUCTION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of GTZ CONSTRUCTION in 27361 PARAISO MANOR, FAIR OAKS RANCH, TX 78015 (NAICS 238130). OSHA activity number 340623743.
Where did this inspection happen?
- Establishment
- GTZ CONSTRUCTION
- Site address
- 27361 PARAISO MANOR
- City
- FAIR OAKS RANCH
- State
- TX
- ZIP
- 78015
- Mailing
- 129 LEGACY TRACE, LA VERNIA, TX 78121
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 12
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B13
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1200.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): On or about May 06, 2015, employees were exposed to fall hazards greater than 6 feet to the ground level below, when working with no fall protection on the ceiling joist of the residential home , while installing the ceiling bracing and first floor decking.
Recent events (2)
- — I (S) $1200
- — Z (S) $2000
1926.1051 A
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1200.00 Reduced
General-duty citation text
29 CFR 1926.1051(a): Stairway(s) or ladder(s) were not provided at all personnel points of access where there was a break in elevation of 19 inches (48 cm) or more, or no ramp, runway, sloped embankment, or personnel hoist was provided: On or about May 06, 2015, employees were exposed to falls greater the 6 feet to the concrete floor below, when climbing the interior and exterior wall bracing of the residential home, while accessing the first floor ceiling joist and installing the floor decking.
Recent events (2)
- — I (S) $1200
- — Z (S) $2000
More inspections at GTZ CONSTRUCTION
SAN ANTONIO, TX—2024-04-10 00:00:00
GTZ CONSTRUCTION
SAN ANTONIO, TX—2023-11-14 00:00:00
GTZ CONSTRUCTION
FAIR OAKS RANCH, TX—2016-12-07 00:00:00
GTZ CONSTRUCTION
SAN ANTONIO, TX—2016-04-27 00:00:00
GTZ CONSTRUCTION
View GTZ CONSTRUCTION's full OSHA safety record →
More inspections in this industry (NAICS 238130)
ENCINITAS, CA—2026-07-13
LOU RIDDLE CONSTRUCTION
MERIDIAN, ID—2026-07-10
IDAHO HOMES CONSTRUCTION LLC
KIMBERLY, WI—2026-07-10
ENRIQUE RESENDIC
METTER, GA—2026-07-10
M.A.P.C CONSTRUCTION, LLC
SLINGER, WI—2026-07-10
RAMIREZ HOME BUILDERS LLC
More inspections in TX
SPRING, TX—2026-07-10
DORSTENER WIRE TECH INC.
FORT WORTH, TX—2026-07-10
RC PROFESSIONAL ROOFING OF TEXAS LLC
CYPRESS, TX—2026-07-10
FEDERICO CARVAJAL GARCIA
SAN ANTONIO, TX—2026-07-10
ED LONG'S METAL WORKS
SAN ANTONIO, TX—2026-07-09
WAREHOUSE RACK COMPANY, LP
Source