WASHINGTON, DC —
OSHA Inspection: WHITING COMPANY
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of WHITING COMPANY in 4735 TILDEN ST NW, WASHINGTON, DC 20003 (NAICS 238170). OSHA activity number 340649292.
Where did this inspection happen?
- Establishment
- WHITING COMPANY
- Site address
- 4735 TILDEN ST NW
- City
- WASHINGTON
- State
- DC
- ZIP
- 20003
- Mailing
- 2707 VERDIS LANE, CROFTON, MD 21114
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238170
- Employees
- 9
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.451 B05 II
- Issued
- Penalty
- Initial $2800.00 · Current $1600.00 Reduced
General-duty citation text
29 CFR 1926.451(b)(5)(ii): The end of a platform greater than 10 feet in length extended over its support more than 18 inches and the platform was not designed and installed so that the cantilevered portion of the platform is able to support employees without tipping, or has guardrails which block employee access to the cantilivered end. a) On May 12, 2015 and at times prior thereto: east-side area of home: employees were working on a pump-jack scaffold whose working platform extended 36 inches beyond the scaffold's horizontal support thereby exposing employees to a fall of 12-15 feet.
Recent events (2)
- — I (S) $1600
- — Z (S) $2800
1926.451 G01 VII
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. a) On May 12, 2015 and at times prior thereto: front area/south-side and eastside of home: employees were working on a pump-jack scaffold without fall protection and were exposed to fall of approximately 12-15 feet while installing the vinyl siding.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1053 B01
- Issued
- Penalty
- Initial $2000.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed. a) On May 12, 2015 and at times prior thereto; side of building; employees were using an extension ladder to access the pump-jack scaffold that was set an estimated 3 feet below the scaffold platform thereby exposing employees to a 12-15 foot fall.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
More inspections in this industry (NAICS 238170)
CLINTON, MO—2026-07-14
TORCHYLO BUILDERS, LLC.
HIGH POINT, NC—2026-07-14
161545 - RHP SIDING LLC
HIGH POINT, NC—2026-07-14
161544 - TRIAD SIDING OF THOMASVILLE INCORPORATED
OXFORD, OH—2026-07-13
R&R SIDING LLC
WINSTON SALEM, NC—2026-07-10
161522 - MS SIDING LLC
More inspections in DC
WASHINGTON, DC—2026-06-30
U.S. DEPARTMENT OF AGRICULTURE
WASHINGTON, DC—2026-06-16
MACY'S
WASHINGTON, DC—2026-06-02
RIGO MULTISERVICES
WASHINGTON, DC—2026-06-02
DDC CPL LLC
WASHINGTON, DC—2026-06-02
DDC CPL LLC
Source