Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: WHITING COMPANY

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of WHITING COMPANY in 4735 TILDEN ST NW, WASHINGTON, DC 20003 (NAICS 238170). OSHA activity number 340649292.

Watch Whiting Company — free Get an email when a new federal OSHA severe-injury report for Whiting Company is published. One employer, no account, unsubscribe in one click.
Establishment
WHITING COMPANY
Site address
4735 TILDEN ST NW
City
WASHINGTON
State
DC
ZIP
20003
Mailing
2707 VERDIS LANE, CROFTON, MD 21114
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238170
Employees
9
Ownership type
A

3 citations on file for this inspection.

1926.451 B05 II

Serious Gravity 10 1 instance 3 exposed
Issued
Penalty
Initial $2800.00 · Current $1600.00 Reduced
29 CFR 1926.451(b)(5)(ii): The end of a platform greater than 10 feet in length extended over its support more than 18 inches and the platform was not designed and installed so that the cantilevered portion of the platform is able to support employees without tipping, or has guardrails which block employee access to the cantilivered end.    a) On May 12, 2015 and at times prior thereto: east-side area of home: employees were working on a pump-jack scaffold whose working platform extended 36 inches beyond the scaffold's horizontal support thereby exposing employees to a fall of 12-15 feet.
Recent events (2)
  • — I (S) $1600
  • — Z (S) $2800

1926.451 G01 VII

Serious Gravity 10 1 instance 3 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.  a)  On May 12, 2015 and at times prior thereto: front area/south-side and eastside of home: employees were working on a pump-jack scaffold without fall protection and were exposed to fall of approximately 12-15 feet while installing the vinyl siding.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1053 B01

Serious Gravity 5 1 instance 4 exposed
Issued
Penalty
Initial $2000.00 · Current $1000.00 Reduced
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed.    a)  On May 12, 2015 and at times prior thereto; side of building; employees were using an extension ladder to access the pump-jack scaffold that was set an estimated 3 feet below the scaffold platform thereby exposing employees to a 12-15 foot fall.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000