OSHA Inspection: PREMIER DENTAL PRODUCTS

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of PREMIER DENTAL PRODUCTS in 10090 SANDMEYER LANE, PHILADELPHIA, PA 19116 (NAICS 339114). OSHA activity number 340651371.

Watch Premier Dental Products — free Get an email when a new federal OSHA severe-injury report for Premier Dental Products is published. One employer, no account, unsubscribe in one click.
Site address
10090 SANDMEYER LANE
City
PHILADELPHIA
State
PA
ZIP
19116
Mailing
10090 SANDMEYER LANE, PHILADELPHIA, PA 19116
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
339114
Employees
40
Ownership type
A

5 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2975.00 · Current $1933.00 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:    a. Forging and Sharpen Department, 51A FAMCO Mechanical Power Press (Model Number 51A FLOOR, Serial Number P-E6UVU51) - Site specific lockout/tagout procedures were not developed and utilized for an employee who changed dies on mechanical presses.  This can lead either to crushing injuries or to the amputation of body parts. Observed On or about May 13, 2015
Recent events (2)
  • — I (S) $1933
  • — Z (S) $2975

1910.147 C06 I

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:    a. Forging and Sharpen Department - The employer did not to conduct periodic inspections of its locktout/tagout procedures.  Observed On or about May 13, 2015
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.217 D09 IV

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.217(d)(9)(iv): The employer did not provide and enforce the use of safety blocks for use whenever dies are being adjusted or repaired in the press:    a. Forging and Sharpen Department, 51A FAMCO Mechanical Power Press (Model Number 51A FLOOR, Serial Number P-E6UVU51) - The employer did not protect the employee who changes the dies on the press, by the proper use of die safety blocks.  This can lead either to crushing injuries or to the amputation of body parts. Observed On or about May 13, 2015
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.217 C02 I A

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $4900.00 · Current $3185.00 Reduced
29 CFR 1910.217(c)(2)(i)(a): Point of operation guards on mechanical power press did not prevent entry of hands or fingers into the point of operation by reaching through, over, under or around the guards:    a. Forging and Sharpen Department - 51A FAMCO Mechanical Power Press (Model Number 51A FLOOR, Serial Number P-E6UVU51).  The employer did not provide guards at the point of operation of the mechanical press, which led to an amputation.  Observed On or about May 13, 2015.
Recent events (2)
  • — I (S) $3185
  • — Z (S) $4900

1910.147 C07 IV

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(c)(7)(iv): The employer did not certify that employee training had been accomplished and kept up to date:    a. Forging and Sharpen Department - The employer did not certify that employee training had been accomplished. Observed On or about May 13, 2015
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340651371.