Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: HPKD INC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of HPKD INC. in 1029 MCCARTNEY STREET, PITTSBURGH, PA 15220 (NAICS 327390). OSHA activity number 340660026.

Watch Hpkd INC. — free Get an email when a new federal OSHA severe-injury report for Hpkd INC. is published. One employer, no account, unsubscribe in one click.
Establishment
HPKD INC.
Site address
1029 MCCARTNEY STREET
City
PITTSBURGH
State
PA
ZIP
15220
Mailing
1029 MCCARTNEY STREET, PITTSBURGH, PA 15220
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327390
Employees
15
Ownership type
A

3 citations on file for this inspection.

1910.107 E02

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $880.00 Reduced
29 CFR 1910.107(e)(2): The quantity of flammable liquids or liquids with a flashpoint greater than 199.4 degrees F (93 degrees C) kept in the vicinity of spraying operations were not at a minimum required for operations or they exceeded a supply for one day or one shift:     a) In the Paint Shop, on or about May 28, 2015 - The quantity of Quick Dry Bronzing Fluid being stored adjacent to the area where employees spray coat burial vaults exceeded the minimum required for one day of painting.
Recent events (2)
  • — I (S) $880
  • — Z (S) $1600

1910.107 E04

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.107(e)(4): The withdrawal of flammable liquids or liquids with a flashpoint greater than 199.4 °F (93 °C) from containers and the filling of containers, including portable mixing tanks, was not done in a suitable mixing room or in a spraying area when the ventilating system was in operation:     a) In the Paint Shop, on or about May 28, 2015 - Quick Dry Bronzing Fluid was transferred from a 55-gallon drum to a pail adjacent to the area where a spray painter spray coats burial vaults.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.107 E09

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.107(e)(9): Flammable liquids or liquids with a flashpoint greater than 199.4 °F (93 °C) for use in spraying operations were transferred from one container to another without both containers being effectively bonded and grounded to prevent discharge sparks of static electricity:    a) In the Paint Shop, on or about May 28, 2015 - Quick Dry Bronzing Fluid was transferred from a 55-gallon drum to a pail adjacent to the area where a spray painter spray coats burial vaults without both containers being bonded and grounded.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340660026.