Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: JE HURLEY CONSTRUCTION INC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JE HURLEY CONSTRUCTION INC in 3687 VETERANS DR, HELENA, MT 59602 (NAICS 236210). OSHA activity number 340662352.

Watch JE Hurley Construction INC — free Get an email when a new federal OSHA severe-injury report for JE Hurley Construction INC is published. One employer, no account, unsubscribe in one click.
Site address
3687 VETERANS DR
City
HELENA
State
MT
ZIP
59602
Mailing
4602 NORTH PARK DR, COLORADO SPRINGS, CO 80918
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236210
Employees
19
Ownership type
A

4 citations on file for this inspection.

1926.403 B02

Serious Gravity 5 2 instances 3 exposed
Issued
Penalty
Initial $1200.00 · Current $1200.00
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification:  a) Construction site: On May 27, 2015 and at time prior, As the controlling employer, JE Hurley Construction Inc. did not ensure it's sub contractor, CVK Electric, LLC, protected their employees in that employees were exposed to shock hazards while using a 120V receptacle designed to be permanently mounted on a wall as a temporary power source.  b) Construction site: On May 27, 2015 and at time prior, employees were exposed to shock hazards while using a 120V receptacle designed to be permanently mounted on a wall as a temporary mounted power source.
Recent events (1)
  • — Z (S) $1200

1926.404 B01 II

Serious Gravity 5 2 instances 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupers for personal protection:  a) Construction site: On May 27, 2015 and at time prior, As the controlling employer, JE Hurley Construction Inc. did not ensure it's sub contractor, CVK Electric, LLC, protected their employees in that employees were exposed to shock hazards while using an electrical box to energize equipment such as but not limited to a fan and monitor.  b) Construction site: On May 27, 2015 and at time prior, employees were exposed to shock hazards while using an electrical box to energize equipment such as but not limited to a fan and monitor.
Recent events (1)
  • — Z (S) $0

1926.405 G01 III B

Serious Gravity 5 2 instances 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.405(g)(1)(iii)(B): Flexible cords and cables were run through holes in walls, ceilings, or floors:  a) Construction site: On May 27, 2015 and at time prior, As the controlling employer, JE Hurley Construction Inc. did not ensure it's sub contractor, CVK Electric, LLC, protected their employees in that employees were exposed to shock hazards while using a flexible cord installed through a wall.  b) Construction site: On May 27, 2015 and at time prior, employees were exposed to shock hazards while using a flexible cord installed through a wall.
Recent events (1)
  • — Z (S) $0

1926.501 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $2000.00
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems:  a) Construction site: On May 27, 2015 and at time prior, employees were exposed to falls while accessing and egressing scaffolding from a flat roof.
Recent events (1)
  • — Z (S) $2000

View JE HURLEY CONSTRUCTION INC's full OSHA safety record →