OSHA Inspection: MELVIN BOWRIN

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MELVIN BOWRIN in 1101 9TH STREET, NE, WASHINGTON, DC 20002 (NAICS 423320). OSHA activity number 340664887.

Watch Melvin Bowrin — free Get an email when a new federal OSHA severe-injury report for Melvin Bowrin is published. One employer, no account, unsubscribe in one click.
Establishment
MELVIN BOWRIN
Site address
1101 9TH STREET, NE
City
WASHINGTON
State
DC
ZIP
20002
Mailing
8500 OLIVER STREET, NEW CARROLLTON, MD 20784
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423320
Employees
2
Ownership type
A

3 citations on file for this inspection.

1926.451 B01

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii):  a)  Front of Building - On or about May 28, 2015, workers were doing stucco work while working from the platform of a scaffold system that was not fully planked thereby exposing employees to a fall hazard of 14 feet 9 inches to the ground.   In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification.  This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
  • — Z (S) $2800

1926.451 E01

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used.    a)  Front of Building -  On or about May 28, 2015, workers were doing stucco work while working from the platform of a scaffold system and they were not provided with a ladder for access thereby exposing employees to a fall hazard of 14 feet 9 inches to the ground.   In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification.  This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
  • — Z (S) $0

1926.451 G01 VII

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section:  a) Front of Building - On or about May 28, 2015, workers were cleaning a block wall while working from the platform of a scaffold system that did not have guardrails installed and were not provided with personal fall arrest system to protect against falls exposing employees to a fall hazard of 14 feet 9 inches to the ground.   In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification.  This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
  • — Z (S) $0

MACY'S

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340664887.