PAPILLION, NE —
OSHA Inspection: JOSE QUINTANILLA AND JULIO ARMANDO AYALA
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of JOSE QUINTANILLA AND JULIO ARMANDO AYALA in 715 BEADLE STREET, PAPILLION, NE 68133 (NAICS 238160). OSHA activity number 340697473.
Where did this inspection happen?
- Establishment
- JOSE QUINTANILLA AND JULIO ARMANDO AYALA
- Site address
- 715 BEADLE STREET
- City
- PAPILLION
- State
- NE
- ZIP
- 68133
- Mailing
- 5415 S. 20TH STREET, OMAHA, NE 68107
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 5
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.307 D01
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $2800.00
General-duty citation text
29 CFR 1926.307(d)(1): Pulley(s) with part(s) seven feet (2.128 m) or less from the floor or work platform were not guarded in accordance with the requirements specified in paragraphs (m) and (o) of this section: 715 Beadle St., Papillion, NE 68133 (Job-site): The employer failed to ensure that a pulley was adequately guarded on the Grip Rite air compressor. Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed.
Recent events (1)
- — Z (S) $2800
1926.307 E03 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.307(e)(3)(i): Vertical and inclined belts were not enclosed by a guard conforming to standards in paragraphs (m) and (o) of this section: 715 Beadle St., Papillion, NE 68133 (Job-site): The employer failed to ensure that the inclined belt was adequately guarded on the Grip Rite air compressor. Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed.
Recent events (1)
- — Z (S) $0
1926.404 B01 III C
- Issued
- Penalty
- Initial $1600.00 · Current $1600.00
General-duty citation text
29 CFR 1926.404(b)(1)(iii)(C): A cord set and plug was not visually inspected before each days use for external defects, such as deformed or missing pins, and such equipment was defective and used: 715 Beadle St., Papillion, NE 68133 (Job-site): The employer failed to ensure that a cord set and plug was not visually inspected before each days use for external defects, such as deformed or missing pins, and such equipment was defective and used. A flexible extension cord that was in use had a missing ground pin.
Recent events (1)
- — Z (S) $1600
1926.501 B13
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $2800.00
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet or more above lower levels was not protected by guardrail systems, safety net systems, or personal fall arrest systems, nor was an alternative fall protection plan which meets the requirements of �1926.502(k) developed and implemented: 715 Beadle St., Papillion, NE 68133 (Job-site): The employer failed to ensure that adequate fall protection was provided for employees who were working on the roof of a home which was approximately 15 feet from a lower level. Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed.
Recent events (1)
- — Z (S) $2800
1926.1053 B01
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $1600.00
General-duty citation text
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: 715 Beadle St., Papillion, NE 68133 (Job-site): The employer failed to ensure the portable ladder being used by employees to access the roof did not extend at least 3 feet above the roof. Abatement certification is required for this violation. Abatement certification sheet is enclosed with the citation.
Recent events (1)
- — Z (S) $1600
More inspections in this industry (NAICS 238160)
FAIRVIEW, TN—2026-07-16
MARVIN PINERA
CARSON CITY, NV—2026-07-16
UNKNOWN/INVALID ESTABLISHMENT
BANNOCKBURN, IL—2026-07-16
ROOFING H.P. LLC
LOXLEY, AL—2026-07-16
CARLOS CHE
BALTIMORE, MD—2026-07-16
VAL CONSTRUCTION INC
More inspections in NE
CRETE, NE—2026-07-15
SMITHFIELD FOODS
OMAHA, NE—2026-07-14
LACO ENTERPRISES, LLC
OMAHA, NE—2026-07-10
WINGSTOP
LINCOLN, NE—2026-07-01
SMITHFIELD PACKAGED MEATS CORP.
LINCOLN, NE—2026-06-30
PATRIOT PLUMBING, HEATING & AC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340697473.