Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: CENTURY METALS & SUPPLIES, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of CENTURY METALS & SUPPLIES, INC. in 1251 NW 165TH STREET, MIAMI GARDENS, FL 33169 (NAICS 332312). OSHA activity number 340707637.

Watch Century Metals & Supplies, INC. — free Get an email when a new federal OSHA severe-injury report for Century Metals & Supplies, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1251 NW 165TH STREET
City
MIAMI GARDENS
State
FL
ZIP
33169
Mailing
1251 NW 165TH STREET, MIAMI GARDENS, FL 33169
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332312
Employees
50
Ownership type
A

3 citations on file for this inspection.

1910.178 P01

Serious Gravity 10 2 instances 10 exposed
Issued
Penalty
Initial $4900.00 · Current $2940.00 Reduced
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition(s):   Instances: 1. On or about June 16, 2015, at the above addressed jobsite, a powered industrial truck (Hyster #5) had a latch for the propane tank missing, exposing the employees to a fire hazard.  2. On or about June 16, 2015, at the above addressed jobsite, a powered industrial truck(Hyster #2) had an inoperable back-up alarm, exposing employees to a struck-by hazard.
Recent events (2)
  • — I (S) $2940
  • — Z (S) $4900

1910.305 G02 III

Other-than-serious 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:    On or about June 16, 2015, at the above addressed jobsite carpentry department, an extension cord lacked strain relief where its cord entered into the attachment plug, exposing employees to an electrical hazard.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 E01

Other-than-serious 1 instance 5 exposed
Issued
Penalty
Initial $0.00 · Current $0.00

Hazardous substances 2270

29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:   On or about June 16,2015, at the above addressed jobsite, the employer did not develop a written hazard communication program while employees were exposed to the use of chemicals such as but not limited to mineral spirits.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340707637.