Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: DYNAMIC FABRICATION AND FINISHING, LLC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of DYNAMIC FABRICATION AND FINISHING, LLC. in 800 WISCONSIN ST, EAU CLAIRE, WI 54703 (NAICS 332999). OSHA activity number 340712926.

Watch Dynamic Fabrication AND Finishing, LLC. — free Get an email when a new federal OSHA severe-injury report for Dynamic Fabrication AND Finishing, LLC. is published. One employer, no account, unsubscribe in one click.
Site address
800 WISCONSIN ST
City
EAU CLAIRE
State
WI
ZIP
54703
Mailing
800 WISCONSIN STREET, EAU CLAIRE, WI 54703
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332999
Employees
85
Ownership type
A

5 citations on file for this inspection.

1910.147 C01

Serious Gravity 10 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $4900.00 · Current $3920.00 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:    (a) Dynamic Fabrication and Finishing, LLC; The employees were performing servicing and maintenance on machines such as but not limited to the plasma welding table, manual welders, robot welders, presses, and other miscellaneous equipment which the employer did not establish an adequate energy control program to prevent hazardous energy release.
Recent events (2)
  • — I (S) $3920
  • — Z (S) $4900

1910.151 C

Serious Gravity 5 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $4200.00 · Current $3360.00 Reduced
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:    (a) Main production area; Employees are exposed to corrosive chemical mixtures including Chem Cote 3026 which contains corrosive chemicals such as but not limited to phosphoric acid and linear alcohol alkoxylate without access to a suitable facility for quick drenching of the body.
Recent events (2)
  • — I (S) $3360
  • — Z (S) $4200

1910.178 A06

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $2240.00 Reduced
29 CFR 1910.178(a)(6): The employer did not ensure that all nameplates or markings were maintained in a legible condition:    (a)Warehouse area; The Caterpillar 5000 lbs. Forklift's name plate was illegible as it was faded and not readable.
Recent events (2)
  • — I (S) $2240
  • — Z (S) $2800

1910.254 D09 III

Serious Gravity 5 1 instance 15 exposed
Issued
Abate by
Penalty
Initial $4200.00 · Current $3360.00 Reduced
29 CFR 1910.254(d)(9)(iii): Cables with damaged insulation or exposed bare conductors were not replace:    (a) Manual welding area; Employees are exposed to welding leads and cables with damaged insulation while performing manual welding operations.
Recent events (2)
  • — I (S) $3360
  • — Z (S) $4200

1910.332 B01

Serious Gravity 5 1 instance 15 exposed
Issued
Abate by
Penalty
Initial $4200.00 · Current $3360.00 Reduced
29 CFR 1910.332(b)(1): Employees were not trained in and familiar with the safety-related work practices required by 1910.331 through 1910.335 that pertained to their respective job assignments:    (a) Manual welding area; Welders have not received basic electrical training for safety-related work practices. Welders are identified as employees who have a higher than normal risk of electrical accident and are required to be trained and familiar with the safety-related work practices of electricity.
Recent events (2)
  • — I (S) $3360
  • — Z (S) $4200

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340712926.