OSHA Inspection: CALLIHAN ELECTRIC, INC.

Unprogrammed Related inspection · Health discipline

On , OSHA opened an unprogrammed Related health inspection of CALLIHAN ELECTRIC, INC. in 120 PINE STREET, ELYRIA, OH 44035 (NAICS 238210). OSHA activity number 340719954.

Watch Callihan Electric, INC. — free Get an email when a new federal OSHA severe-injury report for Callihan Electric, INC. is published. One employer, no account, unsubscribe in one click.
Site address
120 PINE STREET
City
ELYRIA
State
OH
ZIP
44035
Mailing
10359 VERMILION ROAD, OBERLIN, OH 44074
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
7
Ownership type
A

2 citations on file for this inspection.

1926.1126 H04 I

Deleted Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $0.00 Reduced

Hazardous substances 0689

29 CFR 1926.1126(h)(4)(i):  Whenever the employer allows employees to consume food or beverage at a worksite where chromium (VI) is present, the employer did not ensure that eating and drinking areas and surfaces were maintained as free as practicable of chromium (VI):          (a)  Callihan Electric, Inc. 10359 Vermilion Road, Oberlin, Ohio:  On or about June 17, 2015, the employer did not ensure that the area of the office used for eating and drinking was as clean as practicable.  Wipe samples collected from the table in the lunch area revealed hexavalent chromium concentration of 0.5860 ug/cm2 (5.444 ug/ft2).  Employees were exposed to hexavalent chromium and at risk of serious adverse health effects including but not limited to cancer and damage to the nose, throat and lungs.
Recent events (3)
  • — F (S) $0
  • — C (S) $2000
  • — Z (S) $2000

1926.1126 D02 I

Deleted Other-than-serious 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00

Hazardous substances 0689

29 CFR 1926.1126(d)(2)(i):  The employer did not perform initial monitoring to determine the 8-hour TWA exposure for each employee on the basis of a sufficient number of personal breathing zone air samples to accurately characterize full shift exposure on each shift, for each job classification, in each work area.         (a)  Callihan Electric, Inc. 10359 Vermilion Road, Oberlin, Ohio:  On or about June 17, 2015, at the worksite located at 120 Pine Street, Elyria, Ohio, the employer did not conduct initial monitoring of employee exposure to hexavalent chromium (Cr 6+) while performing construction work.  Employees performed construction work in hexavalent chromium regulated areas.  Employees were exposed to hexavalent chromium and were at risk of adverse, serious health effects including but not limited to lung cancer, damage to the nose and throat, and irritation to the eyes and skin.