Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: E.J. WELCH COMPANY

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of E.J. WELCH COMPANY in 3030 HOLMGREN WAY, GREEN BAY, WI 54304 (NAICS 423310). OSHA activity number 340720911.

Watch E.J. Welch Company — free Get an email when a new federal OSHA severe-injury report for E.J. Welch Company is published. One employer, no account, unsubscribe in one click.
Establishment
E.J. WELCH COMPANY
Site address
3030 HOLMGREN WAY
City
GREEN BAY
State
WI
ZIP
54304
Mailing
3030 HOLMGREN WAY, GREEN BAY, WI 54304
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423310
Employees
5
Ownership type
A

6 citations on file for this inspection.

1910.36 D01

Serious Gravity 1 2 instances 1 exposed
Issued
Abate by
Penalty
Initial $1785.00 · Current $1250.00 Reduced
29 CFR 1910.36(d)(1): Employee(s) were not able to open an exit route door from the inside at all times without keys, tools, or special knowledge:  a)    On or about 6/22/2015, The pedestrian doors on the south side of the building labeled as emergency exits were shut with hasps that had wire rod hung in them.
Recent events (2)
  • — I (S) $1249.5
  • — Z (S) $1785

1910.37 A03

Serious Gravity 1 2 instances 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed:   a)    On or about 6/22/2015, the North emergency exit door access aisle was blocked with two skids which only allowed 14" of clearance to pass through.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.176 B

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.176(b): Storage of material created a hazard:  a)    On or about 6/22/2015, storage racks in the warehouse were not bolted to the floor to prevent movement in accordance with ANSI MH 16.1:2008.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.157 C01

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1785.00 · Current $1250.00 Reduced
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:  a)    On or about 6/22/2015, the company had a partially blocked fire extinguisher on  North wall by the emergency exit.
Recent events (2)
  • — I (S) $1249.5
  • — Z (S) $1785

1910.158 C01

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.158(c)(1): The reels and cabinets of standpipe and hose systems were not conspicuously identified:   a)    On or about 6/22/2015, the company had a partially blocked fire hose reel under a storage rack in the warehouse.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.151 C

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:  a)    On or about 6/22/2015, the portable emergency eye wash station did not have any fluid in it and the refill bottle had an expired date on it.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340720911.