Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: DMA, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of DMA, INC. in 665 BROAD STREET, NEW LONDON, CT 06320 (NAICS 811111). OSHA activity number 340737964.

Watch DMA, INC. — free Get an email when a new federal OSHA severe-injury report for DMA, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
DMA, INC.
Site address
665 BROAD STREET
City
NEW LONDON
State
CT
ZIP
06320
Mailing
266 BRIDGE STREET, GROTON, CT 06340
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811111
Employees
19
Ownership type
A

5 citations on file for this inspection.

1910.253 B04 III

Serious Gravity 5 2 instances 7 exposed
Issued
Penalty
Initial $1700.00 · Current $850.00 Reduced
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not seperated from fuel gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire resistant rating of at least one-half hour:   A.  On or about July 6, 2015, New London Store #179, Shop:  In the following locations, oxygen and acetylene cylinders were not separated by a minimum distance of 20 feet or by a 1/2 hour rated fire wall five feet high.  1.  Bay 1, on a welding cart.  2.  Against the north shop wall.
Recent events (2)
  • — I (S) $850
  • — Z (S) $1700

1910.303 B01 II

Serious Gravity 5 1 instance 7 exposed
Issued
Abate by
Penalty
Initial $1700.00 · Current $850.00 Reduced
29 CFR 1910.303(b)(1)(ii): Electrical equipment was not free from recognized hazards, based on the mechanical strength and durability, including, for parts designed to enclose and protect other equipment, the adequacy of the protection thus provided:   A.  On or about July 6, 2015, New London Store #179, near waste barrels:  A 2-receptacle outlet box was missing an outlet cover, exposing employees to electric shock hazards.
Recent events (2)
  • — I (S) $850
  • — Z (S) $1700

1910.303 B02

Serious Gravity 5 4 instances 6 exposed
Issued
Penalty
Initial $1360.00 · Current $680.00 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:   A.  On or about July 6, 2015, New London Store #179, rear wall of shop:  1.  Three 15A 125V relocatable power taps were used against listing and labeling instructions in that they were powered through a flexible extension cord and plugged into each other.  2.  Kenmore 2.4 cubic foot refrigerator was used against listing and labeling instructions in that it was powered through a relocatable power tap.  Listing and labeling instructions require the equipment to be plugged directly into an outlet.
Recent events (2)
  • — I (S) $680
  • — Z (S) $1360

1910.305 B01 II

Serious Gravity 5 2 instances 4 exposed
Issued
Penalty
Initial $1360.00 · Current $680.00 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:  A.  On or about July 6, 2015, New London Store #178:  1.  Back Room:  The General Electric electrical panel was missing a breaker in position #12, leaving an uncovered opening.  The door on the panel was not locked and employees were exposed to the energized 120V bus bar.  2.  Bay 2:  A four-receptacle outlet box mounted on a building support in Bay 2 was missing a knockout on the top, exposing employees to the energized inner conductors.
Recent events (2)
  • — I (S) $680
  • — Z (S) $1360

1910.37 B05

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.37(b)(5): Each doorway or passage along an exit access that could be mistaken for an exit was not marked "Not an Exit" or similar designation or identified by a sign indicating its actual use:  A.  On or about July 6, 2015, New London Store #178, Tire and Storage Room:  The side-hinged door at the back of the building was not provided with a sign indicating it was not intended to be used as an emergency exit.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

DMA INC.