NEW LONDON, CT —
OSHA Inspection: DMA, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of DMA, INC. in 665 BROAD STREET, NEW LONDON, CT 06320 (NAICS 811111). OSHA activity number 340737964.
Where did this inspection happen?
- Establishment
- DMA, INC.
- Site address
- 665 BROAD STREET
- City
- NEW LONDON
- State
- CT
- ZIP
- 06320
- Mailing
- 266 BRIDGE STREET, GROTON, CT 06340
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811111
- Employees
- 19
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.253 B04 III
- Issued
- Penalty
- Initial $1700.00 · Current $850.00 Reduced
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not seperated from fuel gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire resistant rating of at least one-half hour: A. On or about July 6, 2015, New London Store #179, Shop: In the following locations, oxygen and acetylene cylinders were not separated by a minimum distance of 20 feet or by a 1/2 hour rated fire wall five feet high. 1. Bay 1, on a welding cart. 2. Against the north shop wall.
Recent events (2)
- — I (S) $850
- — Z (S) $1700
1910.303 B01 II
- Issued
- Abate by
- Penalty
- Initial $1700.00 · Current $850.00 Reduced
General-duty citation text
29 CFR 1910.303(b)(1)(ii): Electrical equipment was not free from recognized hazards, based on the mechanical strength and durability, including, for parts designed to enclose and protect other equipment, the adequacy of the protection thus provided: A. On or about July 6, 2015, New London Store #179, near waste barrels: A 2-receptacle outlet box was missing an outlet cover, exposing employees to electric shock hazards.
Recent events (2)
- — I (S) $850
- — Z (S) $1700
1910.303 B02
- Issued
- Penalty
- Initial $1360.00 · Current $680.00 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: A. On or about July 6, 2015, New London Store #179, rear wall of shop: 1. Three 15A 125V relocatable power taps were used against listing and labeling instructions in that they were powered through a flexible extension cord and plugged into each other. 2. Kenmore 2.4 cubic foot refrigerator was used against listing and labeling instructions in that it was powered through a relocatable power tap. Listing and labeling instructions require the equipment to be plugged directly into an outlet.
Recent events (2)
- — I (S) $680
- — Z (S) $1360
1910.305 B01 II
- Issued
- Penalty
- Initial $1360.00 · Current $680.00 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: A. On or about July 6, 2015, New London Store #178: 1. Back Room: The General Electric electrical panel was missing a breaker in position #12, leaving an uncovered opening. The door on the panel was not locked and employees were exposed to the energized 120V bus bar. 2. Bay 2: A four-receptacle outlet box mounted on a building support in Bay 2 was missing a knockout on the top, exposing employees to the energized inner conductors.
Recent events (2)
- — I (S) $680
- — Z (S) $1360
1910.37 B05
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.37(b)(5): Each doorway or passage along an exit access that could be mistaken for an exit was not marked "Not an Exit" or similar designation or identified by a sign indicating its actual use: A. On or about July 6, 2015, New London Store #178, Tire and Storage Room: The side-hinged door at the back of the building was not provided with a sign indicating it was not intended to be used as an emergency exit.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at DMA, INC.
View DMA, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 811111)
LONGVIEW, WA—2026-07-09
WA317992006 - LONGVIEW AUTO REPAIR LLC
HOUGHTON LAKE, MI—2026-07-08
WILSON'S AUTOMOTIVE
KELSO, WA—2026-07-08
WA317991989 - THOMAS TRANSMISSIONS LLC
BURTON, MI—2026-07-07
AMERICA'S MOST WANTED 4X4
FISHERS, IN—2026-07-07
PEP BOYS AUTO SERVICE & TIRES
More inspections in CT
BRIDGEPORT, CT—2026-07-10
WRR, INC.
BERLIN, CT—2026-07-10
MMF CONSTRUCTION LLC
NAUGATUCK, CT—2026-07-08
WHITING-TURNER LCT2 JOINT VENTURE
SOMERS, CT—2026-07-08
F&G RECYCLING LLC
STAMFORD, CT—2026-07-07
FAIRFIELD AVENUE MAINTENANCE COMPANY, INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340737964.