On , OSHA opened a complaint safety inspection of KEITH WILLIAMS DBA WILLIAMS PAINTING in 1100 5TH STREET 100#, HIGHLAND, IL 62249 (NAICS 238320). OSHA activity number 340741776.

Watch Keith Williams DBA Williams Painting — free Get an email when a new federal OSHA severe-injury report for Keith Williams DBA Williams Painting is published. One employer, no account, unsubscribe in one click.
Site address
1100 5TH STREET 100#
City
HIGHLAND
State
IL
ZIP
62249
Mailing
1100 5TH STREET 100#, HIGHLAND, IL 62249
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238320
Employees
5
Ownership type
A

7 citations on file for this inspection.

1910.107 C06

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $0.00 Reduced
29 CFR 1910.107(c)(6): Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined were not explosion-proof type approved for  Class I, group D locations and did not otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations:     Extension cords were located and in use within the spray booth area.
Recent events (2)
  • — I (S) $0
  • — Z (S) $1600

1910.107 C08

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.107(c)(8): Portable lamp(s) were used in the spraying area(s) during spraying operations:     Two portable quartz lights were in use within the spray booth area.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.334 A02 II

Serious Gravity 5 3 instances 5 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $800.00 Reduced
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could expose an employee to injury and the defective or damaged item was not removed from service:           One 110 volt extension cord was supplying power to the temporary lighting within the Spray booth and two more 110 volt extension cords that were available for use within the facility were missing their plug end ground pins.
Recent events (2)
  • — I (S) $800
  • — Z (S) $1600

1910.1200 E01

Serious Gravity 1 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $600.00 Reduced
29 CFR 1910.1200(e)(1): Employer had not developed or implemented a written hazard communication program which included the requirements outlined in 29 FR 1910.1200(e)(1)(i) and (e)(1)(ii):                 a)    A written Hazard Communications program had not been developed to inform and train employees to protect them from chemical hazards while working with but not limited to various paints, stains and thinners.
Recent events (2)
  • — I (S) $600
  • — Z (S) $1200

1910.1200 G01

Deleted Serious Gravity 1 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(g)(1): Employers did not have a safety data sheet in the workplace for each hazardous chemical which they use:    The employer did not have safety data sheets for the hazardous chemicals such as, but not limited to various paints, stains and thinners.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 H02 I

Serious Gravity 1 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(h)(2)(i): The employer did not provide information to the employees on the requirements of the Hazard Communication Standard 29 CFR 1910.1200:        Employees had not been trained regarding the use of hazardous chemicals such as but not limited to various paints, stains and thinners.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G01 IV C

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(1)(iv)(C): Flexible cords and cables were run through doorways, windows or floors:     A powered 110 volt flexible cord was run under the doors that were on the front of the Spray Paint Booth.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0