Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: MAXIMUM COATINGS AND SANDBLASTING LLC

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of MAXIMUM COATINGS AND SANDBLASTING LLC in 2521 W. GRAND AVE, WISCONSIN RAPIDS, WI 54494 (NAICS 332812). OSHA activity number 340743566.

Watch Maximum Coatings AND Sandblasting LLC — free Get an email when a new federal OSHA severe-injury report for Maximum Coatings AND Sandblasting LLC is published. One employer, no account, unsubscribe in one click.
Site address
2521 W. GRAND AVE
City
WISCONSIN RAPIDS
State
WI
ZIP
54494
Mailing
5100 COUNTY ROAD M, JUNCTION CITY, WI 54443
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332812
Employees
1
Ownership type
A

4 citations on file for this inspection.

1910.134 C01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1500.00 Reduced
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use:     A written respiratory protection program was not established for employees required to wear supplied air and air purifying respirators.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2000

1910.134 E01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $0.00 Reduced
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:     The employer did not provide a medical evaluation prior to the sand blaster wearing supplied air helmet.
Recent events (2)
  • — I (S) $0
  • — Z (S) $1600

1910.134 I07

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1500.00 Reduced
29 CFR 1910.134(i)(7): Oil lubricated compressor(s) used to supply breathing air did not have a high-temperature or carbon monoxide alarm(s) or both:      The employer did not have a carbon monoxide alarm monitoring the supply breathing air on the diesel powered oil-lubricated air compressor.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2000

1910.134 I05 IV

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(i)(5)(iv): The employer did not ensure that compressors used to supply breathing air to respirators were constructed and situated so as to have a tag maintained at the compressor containing the most recent change date and the signature of the person authorized by the employer to perform the change:    The employer did not have a tag kept or maintained at the compressor that contained the most recent change to the sorbent beds for the air supplied respirators used by the Blasters/painters.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340743566.