MIDDLETOWN, MO —
OSHA Inspection: PET PRO PRODUCTS
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of PET PRO PRODUCTS in 204 E. MAIN STREET, MIDDLETOWN, MO 63359 (NAICS 311119). OSHA activity number 340756766.
Where did this inspection happen?
- Establishment
- PET PRO PRODUCTS
- Site address
- 204 E. MAIN STREET
- City
- MIDDLETOWN
- State
- MO
- ZIP
- 63359
- Mailing
- 204 E. MAIN STREET, MIDDLETOWN, MO 63359
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311119
- Employees
- 5
- Ownership type
- A
Citations
11 citations on file for this inspection.
1910.147 C04 I
- Issued
- Abate by
- Penalty
- Initial $1200.00 · Current $840.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a. A lockout program and procedures were not developed and implemented, including providing training according to the lockout standard requirements, for work such as, changing belts on equipment and clearing elevator (bin drops) of clogged grain. Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
- — I (S) $840
- — Z (S) $1200
1910.212 A03 II
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $1120.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): a. Auger in the soybean unloading bin was not guarded. b. Auger at the bottom of the mixers (floor level) was not guarded. c. At the complete feed extruder, the mixing chamber was not covered/guarded (note: an injury previously occurred). Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
- — I (S) $1120
- — Z (S) $1600
1910.219 B01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.219(b)(1): Flywheel(s) with parts seven feet or less above floor(s) or platform(s) were not guarded in accordance with the requirements specified in 29 CFR 1910.219(b)(1)(i) through (b)(1)(iv): a. At the complete feed extruder, the flywheel was not completely guarded. Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.219 D01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): a. Multiple examples of unguarded belt/pulleys, such as, at the soybean extruder, complete feed extruder vibrating table, and the transfer pipe used at the mixer. Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.219 E01 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs 42 inches or less from the floor level were not fully enclosed by guards conforming to requirements specified in 29 CFR 1910.219(m) and (o): a. Multiple examples of unguarded belt/pulleys, such as, at the soybean extruder, complete feed extruder vibrating table, and the transfer pipe used at the mixer. Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.219 I02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.219(i)(2): Revolving surfaces of shaft coupling(s) were not covered by a safety sleeve: a. At the complete feed extruder, the coupling for the cutter head was not covered or guarded during operation. Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 B02
- Issued
- Abate by
- Penalty
- Initial $1200.00 · Current $840.00 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a. A 110 V duplex outlet was energized by an unsupported length of sheathed cable ("Romex"). The outlet is designed to be mounted and secured. Sheathed cable is not designed to be used as a flexible cord and is required to be supported by a stable surface. Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
- — I (S) $840
- — Z (S) $1200
1910.305 G02 III
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws: a. Numerous examples of damaged strain relief (damaged insulation where the power cord enters an outlet box or at the plug of the power cord) at power cord plugs, such as, at the 110 V power cord to the complete feed extruder motor, and an unsupported duplex outlet box by the storage bins. Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.304 G05
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $1120.00 Reduced
General-duty citation text
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: a. The ground pin was missing from the power cord to the transfer pipe used at the mixer. Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
- — I (S) $1120
- — Z (S) $1600
1910.334 A03 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.334(a)(3)(i): A flexible cord used with grounding type equipment did not contain an equipment grounding conductor: a. At the mixing area, a fan with a three wire power cord was plugged into a two wire extension cord. b. In the storage/production area, a fan with a three wire power cord was plugged into a two wire extension cord (note: up to 100 V was measured on the fan case). Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.334 A03 III
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.334(a)(3)(iii): Adapters which interrupt the continuity of the equipment grounding connection were used: a. At the storage area, a chop saw was plugged into an adapter that by-passed the equipment grounding conductor. Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 311119)
CHILLICOTHE, MO—2026-06-30
MILBANK MILLS INC
SALT LAKE CITY, UT—2026-06-25
INVE AQUACULTURE INC
GREELEY, CO—2026-06-16
GREELEY SEED CO., LLC
HELM, CA—2026-06-15
B&R CUSTOM CHOPPING LLC
LEXINGTON, NE—2026-06-05
LIVESTOCK NUTRITION CENTER
More inspections in MO
KANSAS CITY, MO—2026-07-09
NIAGARA BOTTLING
MONETT, MO—2026-07-09
MONETT METALS INC.
PARKVILLE, MO—2026-07-08
SKY-TECH ROOFING, LLC.
SPRINGFIELD, MO—2026-07-07
D & C CONSTRUCTION, LLC.
JOPLIN, MO—2026-07-07
SERVICE RECYCLING - NORTH PLANT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340756766.