OSHA Inspection: CALABRESE BROTHERS LIMITED LIABILITY COMPANY

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CALABRESE BROTHERS LIMITED LIABILITY COMPANY in 1383 WHITIMARE ROAD, MIDDLEBURY, CT 06762 (NAICS 237110). OSHA activity number 340792365.

Watch Calabrese Brothers Limited Liability Company — free Get an email when a new federal OSHA severe-injury report for Calabrese Brothers Limited Liability Company is published. One employer, no account, unsubscribe in one click.
Site address
1383 WHITIMARE ROAD
City
MIDDLEBURY
State
CT
ZIP
06762
Mailing
4 FOX ROAD, WOODBURY, CT 06798
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237110
Employees
2
Ownership type
A

2 citations on file for this inspection.

1926.651 K01

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $0.00 Reduced
29 CFR 1926.651(k)(1): An inspection of the excavations, the adjacent areas, and protective systems was not conducted by the competent person prior to the start of work and as needed throughout the shift:  Jobsite:  An inspection of the trench, approximately 6 feet 7 inches deep, 26 feet 9 inches long by 7 feet 2 inches wide, and its adjacent areas was not conducted by a competent person for evidence of a situation that could have resulted in a cave-in
Recent events (2)
  • — I (S) $0
  • — Z (S) $2000

1926.652 A01

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $0.00 Reduced
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(c).   Jobsite: The employees, installing reinforced concrete pipe inside the trench which was approximately 6 feet 7 inches deep, 26 feet 9 inches long and 7 feet 2 inches wide, were not protected from cave-ins by utilizing adequate and appropriate cave-in protective systems/devices.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2000

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340792365.