Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: ROBINSON TOOLS LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of ROBINSON TOOLS LLC in 477 WHITNEY ROAD, PENFIELD, NY 14526 (NAICS 332212). OSHA activity number 340807742.

Watch Robinson Tools LLC — free Get an email when a new federal OSHA severe-injury report for Robinson Tools LLC is published. One employer, no account, unsubscribe in one click.
Establishment
ROBINSON TOOLS LLC
Site address
477 WHITNEY ROAD
City
PENFIELD
State
NY
ZIP
14526
Mailing
477 WHITNEY ROAD, PENFIELD, NY 14526
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332212
Employees
4
Ownership type
A

8 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1000.00 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:    a) On or about 07/30/15 in the press area; employer failed to protect employees engaged in service and maintenance activities on mechanical power presses, such as but not limited to, changing dies, cleaning the brake, lubricating parts on the machines, from amputation hazards when they did not require the use locks on energy control devices as described in their written Energy Determination Procedures dated 2013.      ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
  • — J (S) $1000
  • — C (S) $2000
  • — Z (S) $2000

1910.215 A04

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $600.00 Reduced
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch:    a) On or about 07/27/15 in the work bench area of the shop; employer failed to protect employees who used the bench grinder ( Sears brand 1/2 hp ) from caught between hazards and lacerations, when the tool rest was adjusted to a distance of 3/4 inches.      ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
  • — J (S) $600
  • — C (S) $1200
  • — Z (S) $1200

1910.217 C01 I

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1400.00 Reduced
29 CFR 1910.217(c)(1)(i): The employer did not provide and ensure the usage of point of operation guards or properly applied point of operation devices on every operation performed on mechanical power press(es)    a) On or about 07/27/15 in the power press area; employer failed to protect employee operating mechanical power press F-00 ( full revolution - foot pedal activated ) and making the 6 inch part, from an amputation hazard when he reached into the point of operation with the die opening of 2.5 inches and no guarding method used.      ABATEMENT DOCUMENTATION REQUIRED
Recent events (3)
  • — J (S) $1400
  • — C (S) $2800
  • — Z (S) $2800

1910.217 D04

Serious Gravity 10 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.217(d)(4): Guide post(s) on mechanical power press(es) which were separated from their bushing by more than one fourth inch were not protected by point of operation guards or devices in accordance with 29 CFR 1910.217(c);   a) On or about 07/27/15 in the power press area; employer failed to protect employee operating mechanical power press F-00 ( full revolution - foot pedal activated ) and reaching into the die area to insert and remove parts, from an amputation hazard when guide posts on the die were separated approximately 3/4 of an inch, created a caught between hazard and no guarding method was used.      b) On or about 07/27/15 in the press area; employer failed to protect employee operating mechanical power press F-3 ( full revolution press ) operated by two palm buttons and reaching into the die area to insert and remove parts, from an amputation hazard when the guide posts on the die were separated approximately an inch, created a caught between hazard and no guarding method used.        c) On or about 07/27/15 in the press area; employer failed to protect employees operating mechanical power press C-2 ( full revolution mechanical power press ) operated by a two palm buttons and reaching into the die to insert and remove parts, from an amputation hazard when the guide post on the die were separated approximately 1.5 inches created a caught between hazards and no guarding method was used.      ABATEMENT DOCUMENTATION REQUIRED
Recent events (3)
  • — J (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.217 C05 I

Serious Gravity 10 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1400.00 Reduced
29 CFR 1910.217(c)(5)(i): Mechanical power press(es) where the operator feeds or removes parts by placing one or both hands in the point of operation, and a two hand control, presence sensing device, or type B gate or movable barrier guard is used, were not equipped with a control system and a brake monitor which complied with paragraphs b (13 ) and (14) of this section;     a) On or about 07/27/15 in the press area; employees placed and removed parts with one or both hands in the point of operation of the mechanical power press C-2 ( full revolution mechanical power press ) operated by a two palm buttons but not equipped with a control system or brake monitor were exposed to an amputation hazards.       b) On or about 07/27/15 in the press area; employees placed and removed parts with one or both hands in the point of operation of the mechanical power press F-3 ( full revolution mechanical power press ) operated by two palm buttons but not equipped with a control system or brake monitor and were exposed to an amputation hazard.      ABATEMENT DOCUMENTATION REQURIED
Recent events (3)
  • — J (S) $1400
  • — C (S) $2800
  • — Z (S) $2800

1910.217 E01 I

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.217(e)(1)(i): Certification records of mechanical power press inspections and the maintenance work performed, which indicated the date of the inspection, the signature of the person who performed the inspection, and the serial number or other identifier of the power press that was inspected were not maintained:    a) On or about 07/30/15 in the power press area; Employer failed to protect employees involved in operating the mechanical power press(es) from caught between hazards, when they failed to document and maintain the inspections and maintenance performed on the power press where employees placed hands in dies.      ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
  • — J (O) $0
  • — C (O) $0
  • — Z (O) $0

1910.217 E01 II

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.217(e)(1)(ii): Results of the inspection and weekly testing of mechanical power press(es) condition of the anti-repeat feature, single stroke mechanism, and clutch brake mechanism were not documented;     a) On or about 07/30/15 in the power press area; Employer failed to protect employees involved in operating the mechanical power press(es) from caught between hazards, when they failed to document the inspection of the anti-repeat function and operational condition of the mechanical power presses where employees placed one or both hands in dies.          ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
  • — J (O) $0
  • — C (O) $0
  • — Z (O) $0

1910.303 G01 I B

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(g)(1)(i)(B): For electric equipment operating at 600 volts, nominal, or less to ground, and likely to require examination, adjustment, servicing, or maintenance while energized, the width of the working space in front of electrical equipment was less than the width of the equipment or 762 mm (30 inches), whichever was greater :    a) On or about 07/27/15 in the press room; employer failed to protect employees,  involved in operating the circuit breakers for the power presses located in the electrical panel near mechanical power press F-3, from contact with electrical current when the distance of the panel to the power press was nineteen inches.      ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
  • — J (O) $0
  • — C (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340807742.