2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: SG EXTERIOR CONSTRUCTION, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SG EXTERIOR CONSTRUCTION, INC. in 526 PARK AVENUE, RIVER FOREST, IL 60305 (NAICS 238160). OSHA activity number 340812700.

Watch SG Exterior Construction, INC. — free Get an email when a new federal OSHA severe-injury report for SG Exterior Construction, INC. is published. One employer, no account, unsubscribe in one click.
Site address
526 PARK AVENUE
City
RIVER FOREST
State
IL
ZIP
60305
Mailing
6347 WEST ROSCOE STREET, CHICAGO, IL 60634
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
5
Ownership type
A

2 citations on file for this inspection.

1926.501 B13

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1600.00 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system:     a)  Employees performing roofing work were exposed to fall hazards of approximately 21 feet.      In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $1600
  • — Z (S) $2800

1926.1053 B04

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1000.00 Reduced
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed:     a) Employees were exposed to fall hazards while using an A-frame ladder without its metal spreaders or locking devices in the open position on the edge of an unprotected working surface approximately 21 feet high.     In accordance with 29CFR 1903.19(d), abatement certification is required for this violation (using CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement or other written records.