OSHA Inspection: T & J DEVELOPMENT COMPANY

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of T & J DEVELOPMENT COMPANY in 7200 WILLIE G. AVE., WESTOVER, WV 26501 (NAICS 238990). OSHA activity number 340814565.

Watch T & J Development Company — free Get an email when a new federal OSHA severe-injury report for T & J Development Company is published. One employer, no account, unsubscribe in one click.
Site address
7200 WILLIE G. AVE.
City
WESTOVER
State
WV
ZIP
26501
Mailing
250 SCOTT AVE., MORGANTOWN, WV 26508
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238990
Employees
6
Ownership type
A

4 citations on file for this inspection.

1926.403 I02 I

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $960.00 Reduced
29 CFR 1926.403(i)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by cabinets or other forms of enclosures, nor by any of the means listed in subparagraphs (A) through (D) of this paragraph.    a.)  T & J Development Company, 7200 Willie G Ave, Westover WV:  On or about 07/29/15, employees were exposed to the 120 volt unguarded bus bar in the temporary panel box, in that a breaker was missing.    ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (2)
  • — I (S) $960
  • — Z (S) $1600

1926.405 A02 II E

Serious Gravity 5 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $960.00 Reduced
29 CFR 1926.405(a)(2)(ii)(E): Lamps used in temporary wiring for general illumination were not protected from accidental contact or breakage:    a.)  T & J Development Company, 7200 Willie G Ave, Westover WV:  On or about 07/29/15, some of the temporary stringer lights used on site were not protected from accidental contact or breakage.    ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (2)
  • — I (S) $960
  • — Z (S) $1600

1926.405 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $960.00 Reduced
29 CFR 1926.405(b)(1): Unused openings in cabinets, boxes, and fittings were not effectively closed:    a.)  T & J Development Company, 7200 Willie G Ave, Westover WV:  On or about 07/29/15, unused openings in the temporary power panel box were not effectively closed in that there were two missing knockouts.    ABATEMENT CERTIFIATION IS REQUIRED.
Recent events (2)
  • — I (S) $960
  • — Z (S) $1600

1926.453 B02 V

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1680.00 Reduced
29 CFR 1926.453(b)(2)(v): A body belt was not worn and/or a lanyard was not attached to the boom or basket when working from an aerial lift:    a.)  T & J Development Company, 7200 Willie G Ave., Westover WV:  On or about 07/29/15,  employees working from an aerial lift were not protected from falling.    ABATEMENT DOCUMENTATION IS REQUIRED.    Note:  As of January 1, 1998, subpart M of this part (1926.502(d)) provides that body belts are not acceptable as part of a personal fall arrest system.  The use of a body belt in a tethering system or in a restraint system is acceptable and is regulated