Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: WILSON & FRIENDS GENERAL CONSTRUCTION LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of WILSON & FRIENDS GENERAL CONSTRUCTION LLC in 3212 WISCONSIN AVE, MILWAUKEE, WI 53208 (NAICS 238160). OSHA activity number 340816347.

Watch Wilson & Friends General Construction LLC — free Get an email when a new federal OSHA severe-injury report for Wilson & Friends General Construction LLC is published. One employer, no account, unsubscribe in one click.
Site address
3212 WISCONSIN AVE
City
MILWAUKEE
State
WI
ZIP
53208
Mailing
2105 S 17TH ST, MILWAUKEE, WI 53215
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
5
Ownership type
A

9 citations on file for this inspection.

1903.19 D01

Other-than-serious 6 instances 5 exposed
Issued
Abate by
Penalty
Initial $400.00 · Current $400.00
29 CFR 1903.19(d)(1): The employer must submit to the Agency, along with the information on abatement certification required by paragraph (c)(3) of this section, documents demonstrating that abatement is complete for each willful or repeat violation and for any serious violation for which the Agency indicates in the citation that such abatement documentation is required:  The employer failed to provide documentation demonstrating the abatement method and completion of the following hazards of the site, reflected in the citations issued on October 16, 2015:      a)  Employees used pneumatic nail guns without wearing eye protection.     b)  Employees performed roofing tasks on a steeped pitched roof without fall protection devices           installed.     c)  Employees were exposed to fall hazards without being trained on how to recognize and minimize their exposure to           the hazards.     d)  Employees used step ladders in a manner that they were not designed for.     e)  Employees used unsecured ladders on unstable or leveled surfaces.     f)   Employees traveled ladder that were not clear at the top and bottom for safe access and egress.
Recent events (1)
  • — Z (O) $400

1926.100 A

Serious Gravity 1 1 instance 5 exposed
Issued
Penalty
Initial $1200.00 · Current $600.00 Reduced
29 CFR 1926.100(a): At this job site, employees exposed to possible head injury from falling or flying objects or from impact with hand tools, equipment and building materials during construction operations were not wearing hard hats.    (a) The employer did not ensure that employees were using head protection while working under personnel, materials, and equipment.
Recent events (2)
  • — I (S) $600
  • — Z (S) $1200

1926.102 A01

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $0.00 Reduced
29 CFR 1926.102(a)(1): Eye and face protective equipment was not used when machines or operations presented potential eye or face injury:    (a) The employer did not ensure that employees were using eye protection when using pneumatic nail guns.
Recent events (2)
  • — I (S) $0
  • — Z (S) $1600

1926.503 A01

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1400.00 Reduced
29 CFR 1926.503(a)(1): The employer did not train each employee who might be exposed to fall hazards to enable them to recognize fall hazards and the procedures to be followed in order to minimize these hazards:    (a)The employer did not ensure that employees were trained to recognize and protect themselves from fall hazards. Employees conducting roofing operations on a 12:12 pitch roof were not protected from falling to the lower level.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1926.501 B13

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $0.00 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b):     (a) Employees conducting roofing operations on a 12:12 pitch roof were not protected from falling to the lower level.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2800

1926.1053 B01

Serious Gravity 1 1 instance 5 exposed
Issued
Penalty
Initial $1200.00 · Current $600.00 Reduced
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to upper landing surfaces, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladders were used to gain access.    (a) Employees conducting roofing activities used a ladder to access the roof which did not extend at least three feet above the roof edge.
Recent events (2)
  • — I (S) $600
  • — Z (S) $1200

1926.1053 B04

Serious Gravity 10 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $0.00 Reduced
29 CFR 1926.1053(b)(4): Ladders were used for purposes other than the purpose for which they were designed:    a)    A stepladder, designed to be used in the open and braced position, was left in the closed position while an employee utilized it to access/egress the upper portion of the roof.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2800

1926.1053 B06

Serious Gravity 10 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $0.00 Reduced
29 CFR 1926.1053(b)(6):   Ladders shall be used only on stable and level surfaces unless secured to prevent accidental displacement.    (a)   Ladders were being used on unstable and uneven surfaces exposing employees to fall hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2800

1926.1053 B09

Serious Gravity 1 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.1053(b)(9): The area around the top and bottom of ladders was not kept clear:    (A)  Areas around the top and the bottom of the ladders were not kept clear of roofing material.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340816347.