Safety Incidents OSHA Severe Injury Reports · 2015–2025
3,913,242Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: FOUR STAR CONSTRUCTION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of FOUR STAR CONSTRUCTION in LT. GOVERNOR OFFICE BLDG. #18 KOGENS GADE, ST THOMAS, VI 00802 (NAICS 238320). OSHA activity number 340817345.

Watch Four Star Construction — free Get an email when a new federal OSHA severe-injury report for Four Star Construction is published. One employer, no account, unsubscribe in one click.
Site address
LT. GOVERNOR OFFICE BLDG. #18 KOGENS GADE
City
ST THOMAS
State
VI
ZIP
00802
Mailing
PO BOX 301792, ST THOMAS, VI 00803
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238320
Employees
5
Ownership type
A

5 citations on file for this inspection.

1926.451 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1800.00 · Current $150.00 Reduced
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii):    a. On or about 07/22/2015, Four Star Construction, Lt. Governor office Bldg. - #18 Kogens Gade, St Thomas V.I - scaffold area:  Employees were observed working over a tube and frame scaffolds in which its working platforms areas were not fully planked.     NOTE:  Certification and documentation of abatement must be submitted for this citation item as required by 29. CFR 1903.19(c) and (d), respectively.
Recent events (2)
  • — I (S) $150
  • — Z (S) $1800

1926.451 C02

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights did not bear on base plates and mud sills or other adequate firm foundation:  a. On or about 07/22/2015, Four Star Construction, Lt. Governor office Bldg. - #18 Kogens Gade, St Thomas V.I - scaffold area:  Employees were observed working on supported scaffolds which were not placed on base plates and mud sills to provide for stability.   NOTE:  Certification and documentation of abatement must be submitted for this citation item as required by 29. CFR 1903.19(c) and (d), respectively.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 E01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used.  Crossbraces were used as a means of access.  a. On or about 07/22/2015, Four Star Construction, Lt. Governor office Bldg. - #18 Kogens Gade, St Thomas V.I - scaffold area:  No access ladders were provided to employees needing to access at a working level of 12ft., 18 ft. and 24 ft on  supported scaffolds end frame type scaffolds.   NOTE:  Certification and documentation of abatement must be submitted for this citation item as required by 29. CFR 1903.19(c) and (d), respectively.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 G01 VII

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1800.00 · Current $150.00 Reduced
29 CFR 1926.451(g)(1)(vii):   Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.    a.   On or about 07/22/2015, Four Star Construction, Lt. Governor office Bldg. - #18 Kogens Gade, St Thomas V.I - scaffold area: Employees were working over a makeshift scaffold attached to building wall of 12 feet high from the lower level without a conventional fall protection system, such as guardrail, safety net, or personal fall arrest system in place.     Note:  Certification and documentation of abatement must be submitted for this citation item as required by 29. CFR 1903.19(c) and (d), respectively.
Recent events (2)
  • — I (S) $150
  • — Z (S) $1800

1926.501 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1800.00 · Current $150.00 Reduced
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.    a.   On or about 07/22/2015, Four Star Construction, Lt. Governor office Bldg. - #18 Kogens Gade, St Thomas V.I - scaffold area: Employees were exposed to fall hazards while erecting a wood scaffold over a sloped roof with open side or edge a approximate height t of 18 feet above the ground level, without a conventional fall protection system in place.    NOTE:  Documentation of abatement must be submitted for this citation item as required by 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $150
  • — Z (S) $1800

View FOUR STAR CONSTRUCTION's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340817345.