Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: ROBINSON FANS, INC. - FLORIDA FACILITY

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of ROBINSON FANS, INC. - FLORIDA FACILITY in 3955 DRANE FIELD ROAD, LAKELAND, FL 33807 (NAICS 333412). OSHA activity number 340821990.

Watch Robinson Fans, INC. - Florida Facility — free Get an email when a new federal OSHA severe-injury report for Robinson Fans, INC. - Florida Facility is published. One employer, no account, unsubscribe in one click.
Site address
3955 DRANE FIELD ROAD
City
LAKELAND
State
FL
ZIP
33807
Mailing
P.O. BOX 6260, LAKELAND, FL 33807
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Case closed
Last modified
Data loaded
NAICS code
333412
Employees
35
Ownership type
A

3 citations on file for this inspection.

1910.212 A03 II

Serious Gravity 10 2 instances 8 exposed
Issued
Abate by
Penalty
Initial $6300.00 · Current $3780.00 Reduced
29 CFR 1910.212(a)(3)(ii): The point of operation of machines whose operation exposed an employee to injury, was not guarded:  Location:  3955 Drane Field Road Lakeland, FL - Shop  (a)  for the small roller press Niagara Series-5S, Model-5-48 S/N: 60072 metal rolling machine located in the shop area, as observed on or about 8/4/2015.  (b)  for the medium roller press Bertch Type-9, S/N: M-8109 metal rolling machine located in the shop area, as observed on or about 8/4/2015.
Recent events (2)
  • — I (S) $3780
  • — Z (S) $6300

1910.37 A03

Other-than-serious 1 instance 8 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed:  a) At the fabrication shop located at 3955 Drane Field Road Lakeland, Florida, access to the north-east side exit door was obstructed by the Nelson Stud Machine, as observed on or about 08/4/2015.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 G01

Other-than-serious 1 instance 8 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:    a) At the fabrication shop located at 3955 Drane Field Road Lakeland, Florida, access to electrical panel was obstructed by an A frame ladder and a cabinet, as observed on or about 08/4/2015.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View ROBINSON FANS, INC. - FLORIDA FACILITY's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340821990.