Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: WESTBURY SIDING & WINDOWS INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of WESTBURY SIDING & WINDOWS INC. in 316 BELLMORE RD., EAST MEADOW, NY 11554 (NAICS 238170). OSHA activity number 340834449.

Watch Westbury Siding & Windows INC. — free Get an email when a new federal OSHA severe-injury report for Westbury Siding & Windows INC. is published. One employer, no account, unsubscribe in one click.
Site address
316 BELLMORE RD.
City
EAST MEADOW
State
NY
ZIP
11554
Mailing
177 LORING RD., LEVITTOWN, NY 11756
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238170
Employees
12
Ownership type
A

4 citations on file for this inspection.

1926.100 A

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $1100.00 Reduced
29 CFR 1926.100(a):   Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets:      a)  Worksite, Back of home, 316 Bellmore Rd. East Meadow NY - Employee was not wearing a protective helmet and was exposed to being struck by vinyl siding and tools while walking and working below overhead work; on or about 8/8/15.        Note:  The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (2)
  • — I (S) $1100
  • — Z (S) $1600

1926.451 G01 VII

Serious Gravity 5 2 instances 3 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1400.00 Reduced
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.      a)  Worksite, Front of home, 316 Bellmore Rd. East Meadow NY - An employee was working on a pump jack scaffold approximately 15ft above the ground without being protected from falling; on or about 8/8/15.      a)  Worksite, Back of home, 316 Bellmore Rd. East Meadow NY - Employees were working on a pump jack scaffold approximately 15ft above the ground without being protected from falling; on or about 8/8/15.         Note:  The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2000

1926.501 B13

Serious Gravity 5 2 instances 3 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1400.00 Reduced
29 CFR 1926.501(b)(13):   Each employee engaged in residential construction activities 6 feet or more above lower levels was not protected by guardrail systems, safety net systems, or personal fall arrest systems, nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502.      a)  Worksite, Front of home, 316 Bellmore Rd. East Meadow NY - Employees were installing vinyl siding on a residential home while working on the roof of a portico.  The employees were not protected from falling approximately 15ft to the ground below; on or about 8/8/15.    b)  Worksite, Back of home NY, 316 Bellmore Rd. East Meadow NY - Employee was installing vinyl siding on the chimney of a residential home while working on the roof.  The employee was not protected from falling approximately 25ft to the ground below; on or about 8/8/15.    Note:  The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2000

1926.1053 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $1600.00 · Current $1100.00 Reduced
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:      a) Worksite, 316 Bellmore Rd. East Meadow NY - Employees installing siding on a two story residential home.  The employees were accessing the work area by using an extension ladder that was set up approximately 1ft above the landing; on or about 8/8/15.     Note:   Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19.
Recent events (2)
  • — I (S) $1100
  • — Z (S) $1600

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340834449.