Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: STEVE BRICK & BLOCK

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of STEVE BRICK & BLOCK in 706 15TH. ST., SE, WASHINGTON, DC 20013 (NAICS 238140). OSHA activity number 340834977.

Watch Steve Brick & Block — free Get an email when a new federal OSHA severe-injury report for Steve Brick & Block is published. One employer, no account, unsubscribe in one click.
Establishment
STEVE BRICK & BLOCK
Site address
706 15TH. ST., SE
City
WASHINGTON
State
DC
ZIP
20013
Mailing
1112 FIJI AVE., HYATTSVILLE, MD 20785
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
4
Ownership type
A

4 citations on file for this inspection.

1926.100 A

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $1600.00
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets:   a)  Front Yard  On or about 08/04/2015, two masons were exposed to a struck-by hazard from falling brick, masons tools and buckets and were not provided with head protection.   In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (1)
  • — Z (S) $1600

1926.451 G01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $2000.00
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level. Paragraphs (g)(1)(i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold:   a)  Front of House  On or about 08/04/2015, two masons installing face brick on the front of a house where exposed to an 18 foot fall from the platforms of a supported scaffold which had not been provided with standard guardrails or other acceptable means of fall protection.   In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (1)
  • — Z (S) $2000

1926.451 H02 II

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(h)(2)(ii): A toeboard was not erected along the edge of platforms more than 10 feet (3.1 m) above lower levels for a distance sufficient to protect employees below:    a)  Front of House  On or about 08/04/2015, two masons standing on the ground below the 18 foot high scaffold platform were exposed to a struck-by hazard from falling brick, tools and buckets for the scaffold platform was not provided with toe boards or some similar adequate means of restrain.   In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (1)
  • — Z (S) $0

1926.1053 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $2000.00 · Current $2000.00
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, was not provided to assist employees in mounting and dismounting the ladder:   a)  Front of House - On or about 08/04/2015, workers were exposed to an 18 foot fall from the top of an aluminum extension ladder used to access a supported scaffold platform whose top rung was located 2 feet below the platform.   No abatement certification or documentation required for this item.
Recent events (1)
  • — Z (S) $2000

MACY'S