BUFFALO, NY —
OSHA Inspection: BLACK HAT CHIMNEY & FIREPLACE INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of BLACK HAT CHIMNEY & FIREPLACE INC. in 205 CAROLINA STREET, BUFFALO, NY 14201 (NAICS 238140). OSHA activity number 340845726.
Where did this inspection happen?
- Establishment
- BLACK HAT CHIMNEY & FIREPLACE INC.
- Site address
- 205 CAROLINA STREET
- City
- BUFFALO
- State
- NY
- ZIP
- 14201
- Mailing
- 3155 SENECA STREET, WEST SENECA, NY 14224
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 3
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.21 B02
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $730.00 Reduced
General-duty citation text
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury: a) Or about 8/07/15, on jobsite at 205 Carolina Street , Buffalo, NY: Two employees had erected a tubular welded frame scaffold that was 7 sections high and 3 sections long. The employees were not trained by a competent person about the correct procedures for erecting, disassembling, and inspecting the scaffold, and how to recognize any hazards associated with this type of work. b) On or about 8/10/15, on jobsite at 205 Carolina Street , Buffalo, NY: Two employees exposed to a fall of approx. 33 ft. while grinding and repointing brickwork from platforms on a tubular welded frame scaffold were not trained about the pertinent OSHA scaffolding regulations, nature of fall hazards, electrical hazards, load capacities, and proper material handling techniques associated with working from this type of scaffold. They also were not trained about the procedures to control or minimize those hazards. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $730
- — Z (S) $2000
1926.451 C01 II
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $1020.00 Reduced
General-duty citation text
29 CFR 1926.451(c)(1)(ii): Guys, ties, and/or braces were not installed according to the scaffold manufacturer's recommendations or at the closest horizontal member to the 4:1 height and repeated vertically at locations of horizontal members every 20 feet (56.1 m) or less thereafter for scaffolds 3 feet ((0.91 m) wide or less, and every 26 feet (7.9 m) or less therafter for scaffolds greater than 3 feet (0.91m) wide. a) Or about 8/07/15, on jobsite at 205 Carolina Street , Buffalo, NY: Two employees had erected a tubular welded frame scaffold that was 7 sections high and 3 sections long. The height of the scaffold was approx. 33 ft., and the base width was 5 ft. , making the height to base width ratio 6.6. There were no guys, ties, or braces installed to restrain the scaffold from tipping. ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
- — I (S) $1020
- — Z (S) $2800
1926.451 C02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights did not bear on base plates and mud sills or other adequate firm foundation: a) Or about 8/07/15, on jobsite at 205 Carolina Street , Buffalo, NY: Two employees had erected a tubular welded frame scaffold that was 7 sections high and 3 sections long. The 8 legs of the scaffolding had steel base plates which rested upon an uneven grass surface. No mud sills were placed below the base plates. ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 G01 VII
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $1020.00 Reduced
General-duty citation text
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. a) On or about 8/10/15, on jobsite at 205 Carolina Street , Buffalo, NY: Two employees were exposed to a fall of approx. 33 ft. from the west side and north end of the scaffold while grinding and repointing brickwork from platforms on a tubular welded frame scaffold. A top rail and /or mid rail was not in place as required in the above areas. (The south end of the scaffold was used for access). ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
- — I (S) $1020
- — Z (S) $2800
1926.451 B01 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(b)(1)(i): Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) was not installed so that the space between adjacent units and the space between the platform and the uprights were no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary. a) On or about 8/10/15, on jobsite at 205 Carolina Street , Buffalo, NY: Two employees were exposed to a fall of approx. 2 ft. to 33 ft. from gaps in the scaffold platforms that they were standing on while grinding and repointing brickwork on a tubular welded frame scaffold. The gaps were approx. 10 to 12 inches wide. ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 F07
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $730.00 Reduced
General-duty citation text
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:; Such activities were not performed only by experienced and trained employees selected for such work by the competent person. a) Or about 8/07/15, on jobsite at 205 Carolina Street , Buffalo, NY: Two untrained and inexperienced employees erected a tubular welded frame scaffold that was 7 sections high and 3 sections long. The scaffold was not erected under the supervision and direction of a competent person qualified in scaffold erection. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $730
- — Z (S) $2000
More inspections in this industry (NAICS 238140)
MARIANNA, FL—2026-07-13
PRIMETIME MOBILE MASONRY LLC
LOMPOC, CA—2026-07-10
UNKNOWN EMPLOYER
FREEHOLD, NJ—2026-07-10
CRAIG'S MASONRY & HARDSCAPE LLC
CINCINNATI, OH—2026-07-09
ALL AMERICAN CONCRETE LLC
NEW YORK, NY—2026-07-08
JEY CONSTRUCTIONS WORKS CORP
More inspections in NY
POUGHKEEPSIE, NY—2026-07-13
MARCO BOARD HOUSE, INC.
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CORTLANDT MANOR, NY—2026-07-13
RJW RENOVATIONS, LLC
HEMPSTEAD, NY—2026-07-13
NYSDOCCS NASSAU AREA OFFICE
NIAGARA FALLS, NY—2026-07-10
NTVI FEDERAL INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340845726.