Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: MEDIA SOURCE INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of MEDIA SOURCE INC. in 5878 INDUSTRIAL PARKWAY, PLAIN CITY, OH 43064 (NAICS 493190). OSHA activity number 340847334.

Watch Media Source INC. — free Get an email when a new federal OSHA severe-injury report for Media Source INC. is published. One employer, no account, unsubscribe in one click.
Establishment
MEDIA SOURCE INC.
Site address
5878 INDUSTRIAL PARKWAY
City
PLAIN CITY
State
OH
ZIP
43064
Mailing
7858 INDUSTRIAL PARKWAY, PLAIN CITY, OH 43064
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
493190
Employees
70
Ownership type
A

7 citations on file for this inspection.

1910.151 C

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3500.00 · Current $1750.00 Reduced
29 CFR 1910.151(c): Where the eyes or body of any person may be exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body shall be provided within the work area for immediate emergency use. [63 FR 33450, June 18, 1998]  a. Next to the battery charging terminal for the forklifts the employer did not have an eyewash station available, thereby exposing employees to corrosive materials.
Recent events (2)
  • — I (S) $1750
  • — Z (S) $3500

1910.178 L02 III

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1400.00 Reduced
29 CFR 1910.178(l)(2)(iii): All operator training and evaluation shall be conducted by persons who have the knowledge, training, and experience to train powered industrial truck operators and evaluate their competence.  a. The employer did not have a training program for operating the powered industrial vehicles, thereby exposing employees to a struck-by hazard.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1910.178 Q07

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1400.00 Reduced
29 CFR 1910.178(q)(7): Industrial trucks shall be examined before being placed in service, and shall not be placed in service if the examination shows any condition adversely affecting the safety of the vehicle. Such examination shall be made at least daily. Where industrial trucks are used on a round-the-clock basis, they shall be examined after each shift. Defects when found shall be immediately reported and corrected.  a. Employees were operating powered industrial vehicles without examining the vehicles prior to use, thereby exposing employees to a struck-by hazard.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1910.303 B01 II

Serious Gravity 5 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $3500.00 · Current $1750.00 Reduced
29 CFR 1910.303(b)(1)(ii): Mechanical strength and durability, including, for parts designed to enclose and protect other equipment, the adequacy of the protection thus provided;  a. In the warehouse, between the filling stations, there was conduit that had separated from the receptacle box, thereby exposing employees to an electrical hazard.
Recent events (2)
  • — I (S) $1750
  • — Z (S) $3500

1910.303 G01

Other-than-serious 1 instance 5 exposed
Issued
Penalty
Initial $3500.00 · Current $1750.00 Reduced
29 CFR 1910.303(g)(1): Space about electric equipment. Sufficient access and working space shall be provided and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment.    a. The employer had the electrical panels A & B blocked with only 3 inches of clearance for working space, thereby exposing employees to an electrical hazard.
Recent events (2)
  • — I (O) $1750
  • — Z (S) $3500

1910.304 G05

Serious Gravity 5 2 instances 6 exposed
Issued
Abate by
Penalty
Initial $3500.00 · Current $1750.00 Reduced
29 CFR 1910.304(g)(5): Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent, continuous, and effective.  a. In the warehouse, next to the filling station, two large industrial fans were missing grounding pins while in operation, thereby exposing employees to an electrical hazard.
Recent events (2)
  • — I (S) $1750
  • — Z (S) $3500

1910.305 G01 IV A

Serious Gravity 5 2 instances 4 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1400.00 Reduced
29 CFR 1910.305(g)(1)(iv)(A): Use of flexible cords and cables. Unless specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords and cables may not be used: As a substitute for the fixed wiring of a structure;  a.  Adjacent to the Warehouse Managers desk, two extension cords were being used in lieu of permanent wiring, thereby exposing employees to a fire hazard.  b.  Next to the backlist station, there was an extension cord being used in lieu of permanent wiring, thereby exposing employees to a fire hazard.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340847334.