OSHA Inspection: DO RIGHT CONTRACTING

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of DO RIGHT CONTRACTING in 2842 MAPLE AVE., POINT PLEASANT, WV 25550 (NAICS 238160). OSHA activity number 340853852.

Watch DO Right Contracting — free Get an email when a new federal OSHA severe-injury report for DO Right Contracting is published. One employer, no account, unsubscribe in one click.
Site address
2842 MAPLE AVE.
City
POINT PLEASANT
State
WV
ZIP
25550
Mailing
2952 MEADOWBROOK DR., POINT PLEASANT, WV 25550
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
3
Ownership type
A

7 citations on file for this inspection.

1926.403 I02 I

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $1600.00
29 CFR 1926.403(i)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by cabinets or other forms of enclosures, nor by any of the means listed in subparagraphs (A) through (D) of this paragraph.  a.)  Do Right Contracting, 2842 Maple Ave., Point Pleasant, WV:  On or about 08/17/15, the 120 volt live parts of the outlet used to supply power to an extension cord was not guarded to prevent accidental contact.  ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (1)
  • — Z (S) $1600

1926.404 B01 II

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $1600.00
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupers for personal protection.  a.)  Do Right Contracting, 2842 Maple Ave., Point Pleasant, WV:  On or about 08/17/15, ground fault circuit interrupters were not used for protection on the 120 volt 15 ampere receptacle outlets that were used to supply power to extension cords and power tools.  ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (1)
  • — Z (S) $1600

1926.501 B10

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system.  Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system.  a.)  Do Right Contracting, 2842 Maple Ave., Point Pleasant WV:  On or about 08/17/15, employees working on a 3/12 sloped roof were not protected from falling approximately 21' to the ground.  ABATEMENT DOCUMENTATION IS REQUIRED.
Recent events (1)
  • — Z (S) $2800

1926.503 A01

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards:  a.)  Do Right Contracting, 2842 Maple Ave., Point Pleasant WV:  On or about 08/17/15, employees were not provided with training prior to being required to perform roofing activities approximately 21' above the ground.  ABATMEENT DOCUMENTATION IS REQUIRED.
Recent events (1)
  • — Z (S) $0

1926.1053 B01

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $2000.00
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:  a.)  Do Right Contracting, 2842 Maple Ave., Point Pleasant, WV:  On or about 08/17/15, employees were using a Werner extension ladder to access a roof 15' above the ground that was not properly extended 3 feet above the landing surface.  ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (1)
  • — Z (S) $2000

1926.1060 A

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.1060(a): The employer did not provide a training program for each employee using ladders and stairways, as necessary, which would enable each employee to recognize hazards related to ladders and stairways and train each employee in the procedures to be followed to minimize these hazards.  a.)  Do Right Contracting, 2842 Maple Ave., Point Pleasant, WV:  On or about 08/17/15, employees were not trained in ladder safety prior to being required to use a Werner extension ladder to access a roof approximately 15' above the ground.  ABATMEENT CERTIFICATION IS REQUIRED.
Recent events (1)
  • — Z (S) $0

1926.1053 B16

Serious Gravity 1 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $1200.00
29 CFR 1926.1053(b)(16): Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not either immediately marked in a manner that readily identifies them as defective, or tagged with "Do Not Use" or similar language, and were not withdrawn from service until repaired.  a.)  Do Right Contracting, 2842 Maple Ave., Point Pleasant WV:  On or about 08/17/15, employees used a Werner extension ladder to access a roof with the bottom 6" of the left rail broke off.  ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (1)
  • — Z (S) $1200

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340853852.