READING, PA —
OSHA Inspection: P. GLENN SHAUB ROOFING
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of P. GLENN SHAUB ROOFING in 808 CARMAN DRIVE, READING, PA 19610 (NAICS 238160). OSHA activity number 340875426.
Where did this inspection happen?
- Establishment
- P. GLENN SHAUB ROOFING
- Site address
- 808 CARMAN DRIVE
- City
- READING
- State
- PA
- ZIP
- 19610
- Mailing
- 2110 BRESSLER DRIVE, WYOMISSING, PA 19610
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 4
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.501 B13
- Issued
- Penalty
- Initial $2000.00 · Current $2000.00
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) 808 Carman Drive, Reading, PA; Employees were tearing off roofing shingles on a 5/12 pitch residential roof 16 feet above the ground without the use of fall protection, on or about 08/26/2015. No abatement certification or documentation required.
Recent events (1)
- — Z (S) $2000
1926.1053 B01
- Issued
- Penalty
- Initial $1200.00 · Current $1200.00
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) 808 Carman Drive, Reading, PA; Employees used a Werner 28 foot Extension Ladder that was not placed 3 feet above the landing to access and egress the roof work area, on or about 08/27/2015. No abatement certification or documentation required.
Recent events (1)
- — Z (S) $1200
1926.20 B01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.20(b)(1): The employer did not initiate and maintain accident prevention programs as necessary to comply with this part: a) 808 Carman Drive, Reading, PA; The employer did not initiate and maintain an accident prevention program for employees that were engaged in residential roofing and susceptible to injuries and illnesses, on or about 08/27/2015. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
- — Z (O) $0
More inspections in this industry (NAICS 238160)
SIOUX FALLS, SD—2026-07-13
H & R ROOFING OF SOUTH DAKOTA, INC.
HENDERSON, NV—2026-07-13
INTEGRITY ROOFING LLC
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CAMDEN, OH—2026-07-13
ALBERTO MORALES
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR
More inspections in PA
MILTON, PA—2026-07-10
HOMETOWN FOODS CHEF BOYARDEE CO.
SUNBURY, PA—2026-07-10
DEMPSEY UNIFORM & LINEN SUPPLY, INC
LANDISVILLE, PA—2026-07-10
FAIRVIEW DEMOLITION LLC
YORK, PA—2026-07-10
AMERICAN SPECIALTY SYSTEMS INC.
WILLIAMSPORT, PA—2026-07-10
INTERNATIONAL PAINT PROS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340875426.