Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: SUNRISE PHARMACEUTICAL, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SUNRISE PHARMACEUTICAL, INC. in 665 EAST LINCOLN AVE, RAHWAY, NJ 07065 (NAICS 325412). OSHA activity number 340887330.

Watch Sunrise Pharmaceutical, INC. — free Get an email when a new federal OSHA severe-injury report for Sunrise Pharmaceutical, INC. is published. One employer, no account, unsubscribe in one click.
Site address
665 EAST LINCOLN AVE
City
RAHWAY
State
NJ
ZIP
07065
Mailing
665 EAST LINCOLN AVE, RAHWAY, NJ 07065
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325412
Employees
38
Ownership type
A

2 citations on file for this inspection.

1910.147 C04 II

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $2975.00 · Current $1934.00 Reduced
29 CFR 1910.147(c)(4)(ii):   Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D)(h):    a/ Sunrise Pharmaceutical/Rahway NJ Site: Production Areas. At the time of this inspection the sites SOP (standard operating procedures) did not include a lockout procedure for servicing machinery, e.g., changing molds to accommodate a new product.   Specific steps to de-energize the equipment/machinery, control of locking devices, authorized service employees/helpers, rules and techniques were not developed and documented.     Machinery/equipment including but not limited to Tablet, Capsule, Powder Machines; V-Blenders  and Packaging machines.    Observed on/or about 09/01/2015.
Recent events (2)
  • — I (S) $1934
  • — Z (S) $2975

1910.147 C05 I

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(c)(5)(i): Locks, tags, chains, wedges, key blocks, adapter pins, self-locking fasteners, or other hardware were not provided by the employer for isolating, securing or blocking of machines or equipment from energy sources:  a/ Sunrise Pharmaceutical/Rahway NJ Site: Production Areas. At the time of this inspection the employer had not provided the required number of locks, keys, hasp and means to identify locking devices to accommodate more than one person performing work, in that the operators are responsible for maintaining their machines. Machinery/equipment including but not limited to Tablet, Capsule, Powder Machines; V-Blenders and Packaging machines.  Observed on/or about 09/01/2015.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340887330.