Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: JMB TRANSPORTING, INC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of JMB TRANSPORTING, INC in BLDG #2043 BARNETT AVE QUANTICO MARINE CORPS BASE, QUANTICO, VA 22134 (NAICS 238990). OSHA activity number 340890144.

Watch JMB Transporting, INC — free Get an email when a new federal OSHA severe-injury report for JMB Transporting, INC is published. One employer, no account, unsubscribe in one click.
Site address
BLDG #2043 BARNETT AVE QUANTICO MARINE CORPS BASE
City
QUANTICO
State
VA
ZIP
22134
Mailing
10 HAMMEN AVENUE, TIMONIUM, MD 21093
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238990
Employees
7
Ownership type
A

3 citations on file for this inspection.

1926.501 B10

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1960.00 Reduced
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest system.  (a) Date of Violation: 09-04-15,Location: Building#2043 Barnett Ave. Quantico Marine Corps Base; Quantico, VA 22134: An employee was not protected from a fall from heights of 13.5 feet while cutting, separating, disassembling and altering a Modspace trailer roof to prepare for transport.  Abatement certification required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, date and method of abatement, and states employee(s) and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $1960
  • — Z (S) $2800

1910.303 B02

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $1120.00 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment (temporary extension cord sets) were not used in accordance with instructions included in the listing or labeling:  a) Date of Violation: 09-01-15,Location: Building#2043 Barnett Ave. Quantico Marine Corps Base; Quantico, VA 22134: Employee(s) were exposed to electrical hazards by using three (3) temporary electrical cordsets plugged into one another, coming from a portable truck mounted generator to power a 6 Gallon 150 PSI Porter-Cable Air Compressor; Model #C2002, Type 9, Serial #2068165872 to power a pneumatic air nailer.  Abatement certification required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, date and method of abatement, and states employee(s) and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $1120
  • — Z (S) $1600

1910.304 B02 II

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.304(b)(2)(ii): Cord connectors having grounding contacts did not have contacts that were effectively grounded.   a) Date of Violation: 09-01-15, Location: Building#2043 Barnett Ave. Quantico Marine Corps Base; Quantico, VA 22134: Employee(s) were exposed to electrical hazards by using one temporary electrical cordsets with no ground pin and plugged into (daisy-chained) two other cordsets, coming from a portable truck mounted generator to power a 6 Gallon 150 PSI Porter-Cable Air Compressor; Model #C2002, Type 9, Serial #2068165872 to power a pneumatic air nailer.   Abatement certification required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, date and method of abatement, and states employee(s) and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0