2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: CHECKERS INDUSTRIAL PRODUCTS, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of CHECKERS INDUSTRIAL PRODUCTS, LLC in 701 EAST SPRING STREET, TITUSVILLE, PA 16354 (NAICS 326199). OSHA activity number 340893445.

Watch Checkers Industrial Products, LLC — free Get an email when a new federal OSHA severe-injury report for Checkers Industrial Products, LLC is published. One employer, no account, unsubscribe in one click.
Site address
701 EAST SPRING STREET
City
TITUSVILLE
State
PA
ZIP
16354
Mailing
701 EAST SPRING STREET MAILBOX 9, TITUSVILLE, PA 16354
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
80
Ownership type
A

6 citations on file for this inspection.

1910.147 C06 I

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $4000.00 · Current $2400.00 Reduced
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed:     a) Alturnamats, 701 E. Spring Street in Titusville, PA.  On or about September 1, 2015, and times prior thereto, periodic inspections of the written lockout/tag-out procedures were not conducted at least annually.
Recent events (2)
  • — I (S) $2400
  • — Z (S) $4000

1910.147 E01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(e)(3): If an authorized employee who applied a lockout or tagout device is not available to remove it, specific procedures and training for the removal of the device were not developed, documented and incorporated into the employer's energy control program:   a) Alturnamats, 701 E. Spring Street in Titusville, PA.  On or about September 1, 2015, and times prior thereto, the written program, provided by the company did not include specific procedures and training for the removal of LO/TO devices by persons other than the employee who applied the device.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A01

Serious Gravity 5 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $4000.00 · Current $2400.00 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by moving parts:     a) CNC machining area, on or about September 1, 2015, and times prior thereto, the Cosmec CNC routers were not guarded to prevent operators and other employees in the area from being caught in and/or struck by the moving gantry and router head.  Pinch points were created between the machines table and moving parts.
Recent events (2)
  • — I (S) $2400
  • — Z (S) $4000

1910.305 G01 IV

Serious Gravity 5 2 instances 40 exposed
Issued
Abate by
Penalty
Initial $5000.00 · Current $3000.00 Reduced
29 CFR 1910.305(g)(1)(iv): Flexible cords and cables were used in a manner prohibited by items A through F of this section:     a) Flaming Area, on or about September 1, 2015, and times prior thereto, extension cords were used in lieu of permanent wiring to supply power to the large, industrial fans.    b) Cleaning, Press and CNC Areas, on or about September 1, 2015, and times prior thereto, the power cords of the pedestal fans were concealed under the concrete floor in the production areas.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $5000

1910.334 A01

Serious Gravity 5 1 instance 40 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.334(a)(1): Flexible electric cords connected to equipment were handled in a manner which will cause damage:   a) Cleaning, Press and CNC Areas, on or about September 1, 2015, and times prior thereto, the power cords of the pedestal fans were run through conduit under the concrete floor in the production areas routing of power cords from pedestal fans
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.334 A02 II

Serious Gravity 5 2 instances 40 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.334(a)(2)(ii): If there is a defect or evidence of damage that might expose an employee to injury, the defective or damaged item was not removed from service, and no employee may use it until repairs and tests necessary to render the equipment safe have been made:  a) Flaming Area, on or about September 1, 2015, and times prior thereto, extension cords, used supply power to the industrial fans, were damaged in that the outer sheathing was melted and cracked, exposing the inner wiring.   b) Cleaning, Press and CNC Areas, on or about September 1, 2015, and times prior thereto, the power cords of the pedestal fans were damaged in that the outer sheathing was cracked and torn, exposing the inner wiring.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View CHECKERS INDUSTRIAL PRODUCTS, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340893445.