LITTLE NECK, NY —
OSHA Inspection: SUPER POWER CONSTRUCTION INC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of SUPER POWER CONSTRUCTION INC in 50-35 DEEPDALE PLACE, LITTLE NECK, NY 11362 (NAICS 236115). OSHA activity number 340894724.
Where did this inspection happen?
- Establishment
- SUPER POWER CONSTRUCTION INC
- Site address
- 50-35 DEEPDALE PLACE
- City
- LITTLE NECK
- State
- NY
- ZIP
- 11362
- Mailing
- 33-70 PRINCE STREET, FLUSHING, NY 11354
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236115
- Employees
- 3
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.100 A
- Issued
- Penalty
- Initial $2000.00 · Current $1200.00 Reduced
General-duty citation text
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a) On or about September 3, 2015- job site at 50-35 Deepdale Place, Little Neck, NY 11362 the employer permitted an employee to work below a scaffold where over head brick work was being performed without a protective helmet. WRITTEN ABATEMENT CERTIFICATION IS NOT REQUIRED.
Recent events (2)
- — I (S) $1200
- — Z (S) $2000
1926.451 B01 II
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $1680.00 Reduced
General-duty citation text
29 CFR 1926.451(b)(1)(ii): The platform was not planked or decked as fully as possible and the remaining open space between the platform and the uprights exceeded 9.5 inches (24.1 cm): a) On or about September 3, 2015- job site at 50-35 Deepdale Place, Little Neck, NY 11362 the employer permitted employees to work on a tubular welded frame scaffold, approximately 11 feet 9 inches above the next lower level, that was not fully planked. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (2)
- — I (S) $1680
- — Z (S) $2800
1926.451 B04
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(b)(4): Each end of a platform, unless cleated or otherwise restrained by hooks or equivalent means, shall extend over the centerline of its support at least 6 inches (15 cm): a) On or about September 3, 2015- job site at 50-35 Deepdale Place, Little Neck, NY 11362 the employer permitted employees to work on a tubular welded frame scaffold, approximately 11 feet 9 inches above the next lower level, whose planks did not extend at least 6 inches over its support. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 C02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates, mud sills or other adequate firm foundation: a) On or about September 3, 2015- job site at 50-35 Deepdale Place, Little Neck, NY 11362 the employer permitted employees to work on a tubular welded frame scaffold, approximately 11 feet 9 inches above the next lower level, that did not have base plates or mud sills installed on the support legs. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 F03
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(f)(3): Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: a) On or about September 3, 2015- job site at 50-35 Deepdale Place, Little Neck, NY 11362 the employer permitted employees to work on a tubular welded frame scaffold, approximately 11 feet 9 inches above the next lower level, that was not inspected by a competent person prior to use. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 G01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level: a) On or about September 3, 2015- job site at 50-35 Deepdale Place, Little Neck, NY 11362 the employer permitted employees to work on a tubular welded frame scaffold, approximately 11 feet 9 inches above the next lower level, without fall protection. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 236115)
REDDING, CA—2026-07-10
R&A RESOURCES, INC.
FRANCESTOWN, NH—2026-07-10
JM BUILDERS LLC
SAN JOSE, CA—2026-07-09
WALT OXLEY ENTERPRISES, INC.
BATAVIA, OH—2026-07-09
FISCHER SINGLE FAMILY HOMES IV, LLC
SARATOGA SPRINGS, UT—2026-07-09
JESSI CONSTRUCTION & PAINTING LLC
More inspections in NY
POUGHKEEPSIE, NY—2026-07-13
MARCO BOARD HOUSE, INC.
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CORTLANDT MANOR, NY—2026-07-13
RJW RENOVATIONS, LLC
HEMPSTEAD, NY—2026-07-13
NYSDOCCS NASSAU AREA OFFICE
NIAGARA FALLS, NY—2026-07-10
NTVI FEDERAL INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340894724.